22
engages, always wait until the motor has stopped before skipping to the next cycle. You can
hear the valve motor while it is repositioning the valve at the beginning of each cycle. Once
the motor has stopped moving (no more noise), press the REGENERATION ICON again to
advance to the rinse stage of the regeneration cycle.
The control valve will continue to keep time and the passage of days for a minimum of 48
hours in the event of a power failure.
CHANGING TIME OF DAY
The current day of the week and time is displayed in the top left corner of the home screen.
It is important that the day and time be accurate so that the flush cycle(s) will occur at the
correct time of the day and so that the diagnostic and data gathering functions of the control
valve will be accurate.
If the day and time are flashing, it means that there has been a power failure and the day
and time need to be checked.
To change the time of day, touch the day and time display in the top left corner of the home
screen and the following screen will appear:
Touch the grey box associated with the year. 2 blue arrows will appear. Touch the blue
arrow on the left to decrease the year. Touch the blue arrow on the right to increase in the
year. Adjust the year by touching the arrows until it is correct.