Installer Manual
Microvideo srl
www.microvideo.eu
43
CHAPTER 4– Programming Control Panel
Inser.Man. RA
(0...65000)
Value (ohm) of RA Resistence (Alarm Resistence)
Inser.Man. RT
(0...65000)
Value (ohm) of RT Resistence (Tamper Resistence)
RADIO ZONES
Parameter
Options
Description
Enable
Yes
Zone Enabled
No
Zone Disabled
Description
20 characters
Description of the zone. Description apprears during configuation: by Keyboard, by
SynergyPro SW, in logs, in SMS messages concerning the zone.
Exclusion Type
Auto-excludable
It represents a zone that can be temporarily Excluded (in a plant inserting) if it appears
alarmed during Area Arming
Not Excludible
You can never Exclude that zone, so you always must "estimate" it during Plant Arming
DelayTime
(0..65000)
Delay time (seconds) in the area if ZONE type is Delayed
NoInsNotReady
Yes
During Inserting System if this Zone is in alarm is Prevented the same Plant Equipment
No
The system can be armed (see "Type Exclusion" and " Forced Ins. ") even if this Zone is in
alarm during insertion system
Zone Type
Snapshot
The Zone, in case of unbalance, generates an alarm Immediatly
Delayed
The Zone, in case of unbalance, generates an alarm after delay time
Firefighting
ALWAYS armed Zone, every unbalance generates an alarm
Antirobbery
ALWAYS armed Zone, every unbalance generates an alarm
No Panic
ALWAYS armed Zone, every unbalance generates an alarm
24H
ALWAYS armed Zone, every unbalance generates an alarm
Technological
ALWAYS armed Zone, every unbalance generates an event, never alarms
Follow/Chase
If the Zone that must be chased is at rest the other one behaves as "Snapshot"
Alarm Cycles
(NoConfig,0..127)
Alarm cycles after which the alarms of the Zone will be ignored for that specific insertion,
however they will continue to be saved into the Log
Areas
(Area1..Area12)
Configuration of the areas the Zone belongs to
And/Or
AND
The Zone is inserted if ALL AREAS it belongs to are armed
OR
The Zone is inserted if LEAST one AREA it belongs to is armed
Test
Yes
Every alarm generation does not trigger any Event , but only Log
No
Every alarm generation triggers both Events and Logs
ZoneToChase
(Zone1..Zone73)
If the zone is “following” type, this parameter indicates the zone that must be followed
(RadioZone1..
RadioZone64)
If the zone is “following” type, this parameter indicates the Radio zone that must be
followed
RF ID Module
(NoConfig,1..64)
Radio module that is associated with this Radio Zone
RF Mod. Input
(1...2)
Input of the radio module that is associated with the Zone RADIO:
1
→
magnet / NC / Infrared
2
→
shutter / NC / Inertial
Input Type
All/Rip
The radio module communicates both the alarm and resting Zone (Dip Switch 4 to ON)
Only Alarm
The radio module communicates ONLY the Rest Zone (Dip Switch 4 OFF)
Outputs
OK
Install Menu
3)Radio Zone
OK
Radio Zones
Radio Zone 1
Radio Zone 1
Enabled
Output 1
Enable
OK
OK
3)Outputs