CHAPTER 4– Programming Control Panel
Parameter Options
Description
Enable
Yes
Enabled Output
NO
Disabled Output
Description
12 characters Output Description. It appears during configuration, by keyboard and SynergyPro SW, in logs, and in
SMS messages, realtive to that output
Default
NC
Normally closed
NO
Normally Open: N.B. For Relè Outputs Default Status is NO, this Status can’t be changed and shows
that COM is short-circuited on NC terminal.
Type
Fix
It is a bistable output rising from its default state to complementary state .
Manual reset: is a type of output that is to be reset to "manually" through an action
Impulsive
It is a monostable output of 50% duty-cycle for a programmable number of cycles. Automatic Reset:
resets by itself
Siren
It is a monostable output with duty-cycle of 80% for a programmable number of cycles. Automatic
Reset: resets by itself
AND Zones
Parameter
Options
Description
Zone A
(NoConfig,Zone1..Zone73) Configuration of the first of the two AND wired zones
(RadioZone1.. RadioZone64) Configuration of the first of the two AND Radio zones
Zone B
(NoConfig,Zone1..Zone73) Configuration of the Second of the two AND wired zones
(RadioZone1.. RadioZone64) Configuration of the Second of the two Radio wired zones
Time
(0...300)
Time (seconds) within which BOTH the two zones must be unbalanced because an alarm event is generated
Direction
NO
The order in which the Zones are unbalanced is not important to generate an alarm event
YES
The order in which the Zones are unbalanced is important to generate an alarm event.
Because ana alarm event is generated it must unbalance first the zone relative to the field ID_ZONE1 and
then, later, within the time specified in the TIMER must be unbalanced in the zone indicated with ID_ZONE2
Expansions
Parameter Options
Description
Enable
YES
Enables expansion
NO
Disables expansion
NOTE: If you disable an expansion you can’t handle in any way all of informations generated by
the expansion itself (tamper, zones, outputs).
Description
12 characters
Description of the expansion. Description appears during configuration, either by keyboard then
by SynergyPro SW, in every log, and in SMS messages relative to expansion
Areas
An area is a group of zones.
This grouping can be done for "geographical" reasons, such as the "First floor" area could
Install Menu
5) AND Zones
OK
OK
4) AND Zones
AND 1 Zone
AND 1 Zone
A Zone
OK
Install Menu
6)Expansions
Expansions
Expansions 1
OK
Expansion 1
Enable
OK
Install Menu
7)Areas
Areas
Area 1
OK
Area 1
Description
Summary of Contents for Synergy SY800