RFID Keys
Parameter Options
Description
Enable
Yes
Enabled Key
NO
Disabled Key
Description
12 charatcters
Key Description. Description appears during configuration, either by keyboard then by
SynergyPro SW, in every log, and in SMS messages relative to key
Serial N.
(ReadONly)
Allows to display serail number of relative key
Patrol Func.
Yes
Patrol Key
NO
User key
Macro
(NoConfig,Macro1...Macro36) Macro configuration to bind to the key
Timer
(NoConfig,Timer1..Timer25)
Timer configuration to bind to the key
Areas
(Area1..Area12)
Areas configuration which the keybelongs to
Acquiring
(Numero Seriale)
Activates the function of acquiring of key serial number to record it in the System.
PROCEDURE OF key ACQUISITION
1) Enter in RFID keys "Acquisition" menu
2) Move the key to the keyboard until the second line of the display shows the serial
number associated with the key
3) Press OK button to finish the procedure
Readers
Parameter
Options
Description
Enable
YES
Reader enabled
NO
Reader disabled
Description
12 Characters
Reader Description. Description appears during configuration, either by keyboard then by
SynergyPro SW, in every log, and in SMS messages relative to reader
Macro 1
(NoConfig,Macro1..Macro36)
Setting of the macro to associate to Red Led
Macro 2
(NoConfig,Macro1..Macro36)
Setting of the macro to associate to Green Led
Macro 3
(NoConfig,Macro1..Macro36)
Setting of the macro to associate to Orange Led
Macro 4
(NoConfig,Macro1..Macro36)
Setting of the macro to associate to Yellow Led
Areas
(Area1...Area12)
Setting of the macro to which reader belong to
WALL Modules
OK
Install Menu
10)RFID Keys
RFID Keys
Key 1
OK
Key 1
Enable
OK
Install Menu
11)Readers
Readers
Reader 1
OK
Reader 1
Enable
OK
Install Menu
12)WALL (VIDEO)
WALL (VIDEO)
WALL 1
OK
WALL 1
Enabled
Summary of Contents for Synergy SY800
Page 1: ...1 ...
Page 60: ...Installer Manual Microvideo srl www microvideo eu 60 ...