MDS 05-2806A01, Rev. E.1
MDS iNET 900 Series User’s Guide
121
4.1.6 Logged Events
(See
View Event Log on Page 81
)
The following events allow the transceiver to continue operation and do
not make the
PWR
LED blink. Each is reported through an SNMP trap.
General System
Error
Internal checks suggest unit
is not functioning properly
Reboot the transceiver
Initialization Error
Unit fails to complete boot
cycle
Contact factory Technical
Services for assistance
Invalid IP Address
The IP address is either
0.0.0.0 or 127.0.0.1
Program IP address to
something other than 0.0.0.0
or 127.0.0.1
MAC Failure
The monitor task reads the
LinkStatus from the MAC
every second. If the MAC
does not reply 10
consecutive times
(regardless of what the result
is) the CPU assumes the
transceiver has lost
communication to the MAC.
Contact factory Technical
Services for assistance
Network Interface
Error
Unit does not recognize the
LAN interface
Contact factory Technical
Services for assistance
Network Name Not
Programmed
Network name is “Not
Programmed”
Change Network Name to
something other than “Not
Programmed”
PLL Out-of-Lock
The FPGA reports a
synthesizer out-of-lock
condition when monitored by
the CPU.
Contact factory Technical
Services for assistance.
Power Control
Railed High
Power control can no longer
compensate and reaches the
high rail
Contact factory Technical
Services for assistance
Power Control
Railed Low
Power control can no longer
compensate and reaches the
low rail
Contact factory Technical
Services for assistance
RSSI Exceeds
Threshold
The running-average RSSI
level is weaker (more
negative) than the
user-defined value.
Check aiming of the
directional antenna used at
the Remote; or raise the
threshold level to a stronger
(less-negative) value.
Table 4-6. Correcting Alarm Conditions—Alphabetical Order
Event Log Entry
Generating Condition
Clearing Condition
or Action
Summary of Contents for iNET 900 Series
Page 10: ...2 MDS iNET 900 Series User s Guide MDS 05 2806A01 Rev E 1 ...
Page 26: ...18 MDS iNET 900 Series User s Guide MDS 05 2806A01 Rev E 1 ...
Page 118: ...110 MDS iNET 900 Series User s Guide MDS 05 2806A01 Rev E 1 ...
Page 120: ...112 MDS iNET 900 Series User s Guide MDS 05 2806A01 Rev E 1 ...
Page 136: ...128 MDS iNET 900 Series User s Guide MDS 05 2806A01 Rev E 1 ...
Page 148: ...140 MDS iNET 900 Series User s Guide MDS 05 2806A01 Rev E 1 ...
Page 150: ...142 MDS iNET 900 Series User s Guide MDS 05 2806A01 Rev E 1 ...
Page 164: ...156 MDS iNET 900 Series User s Guide MDS 05 2806A01 Rev E 1 ...
Page 172: ...164 MDS iNET 900 Series User s Guide MDS 05 2806A01 Rev E 1 ...