Chapter 5
Verification
Page 5-8
CM System User’s Manual
Verifying Operation
Accurate alignment and test measurement requires that the radio warm up with covers in
place for 45 to 60 minutes. Set up and connect the local maintenance terminal (LMT) to
the radio as Chapter 4 outlines. Refer to Appendix B for QuikLink operation with the
LMT.
DC Voltages
If not already in, insert fuses while monitoring primary (line) voltage.
If fuses blow, check for reversed battery connections, incorrect fuse value, faulty power
supply unit or power harness cable/connections. Table 5-C lists radio fuse requirements.
Ensure the module fail LED on the PSU is off; which indicates normal operation.
Check primary and secondary voltages at the test points on the front of the RF PSU and
SP PSU.
Record the values in Table 5-F. Replace the radio cover and allow 45 to 60 minutes for
for the radio to warm up.
System Configuration
Check the system configuration using QuikLink and the LMT–a VT100 compatible
terminal connected to the local access port (see Chapter 4).
After connecting the LMT to the radio, reset the ACU by re-seating it or pressing S4–the
ACU reset switch. The ACU module fail LED blinks for several seconds as the ACU
code initializes and then the LED goes off to indicate normal ACU operation.
The LMT displays the QuikLink main screen that shows the radio frequency band, ACU
code part number, and code revision.
Press <Escape> for the main menu. See Appendix B for QuikLink operation.
Check local radio parameters using the QuikLink
CONFIGURATION
menu. Select
MODULE
PARAMETERS
(screen 51) and check that your radio parameters agree with the required
radio configuration. If you discover discrepancies, check module jumper and switch
settings and seating.
Press <Escape> twice to return to the main menu (screen 002).
SP Operation
At the QuikLink main menu (002) select
CONTROL
AND
MAINTENANCE
and then
PATH
SWITCHING
(screen 71).
On a protected system, set transmit and receive paths of all modules to A and lock their
online state. Press <Escape> to go back to the Control and Maintenance menu and select
LOOPBACK
. Select
IF
LOOPBACK
and place each path in local loopback (A and B sides on
protected systems).
Verify that the data signals (voice and data channels, or orderwire calling number, if
equipped) pass error-free and without alarms on the modules.
Switch the transmit and receive paths to the B-side and verify that data passes error free
on the secondary side.
Table 5-C. Fuse Ratings
Battery
RF PSU Fuse
SP PSU Fuse
±24 V
10A
5A
±48 V
5A
3A
Summary of Contents for CM7
Page 2: ......
Page 4: ...Page iv 5 04 05 CM7 8 100Base T System User s Manual ...
Page 16: ...Glossary Page xvi CM System Users Manual X Y Z ...
Page 24: ...Microwave Networks CM7 8 100Base T System User s Manual Pagexxiv ...
Page 62: ...Chapter 2 Operation Page 2 18 5 02 05 CM 100Base T System User s Manual ...
Page 64: ...Chapter 3 Module Descriptions Page 3 2 CM7 8 100Base T ...
Page 88: ...Section 3 3 Transmitter Unit Page 3 3 6 CM7 8 System User s Manual ...
Page 96: ...Section 3 5 RF Power Supply Unit Page 3 5 4 CM System User s Manual ...
Page 100: ...Section 3 6 SP Power Supply Unit Page 3 6 4 CM System User s Manual ...
Page 106: ...Section 3 7 Alarm and Control Unit Page 3 7 6 11 18 03 CM 100Base T System User s Manual ...
Page 124: ...Section 3 11 SYNDES Page 3 11 6 CM System User s Manual ...
Page 130: ...Section 3 12 SCU Page 3 12 6 11 18 03 CM 100Base T System User s Manual ...
Page 138: ...Section 3 13 OWU Page 3 13 8 CM System User s Manual ...
Page 150: ...Section 3 15 NMU Page 3 15 6 CM System User s Manual ...
Page 192: ...Chapter 5 Verification Page 5 20 CM System User s Manual ...
Page 194: ...Chapter 6 Maintenance Page 6 2 7 23 03 CM 100Base T System User s Manual ...
Page 224: ...Chapter 6 Maintenance Page 6 32 7 23 03 CM 100Base T System User s Manual ...
Page 226: ...Site Engineering Page 2 CM System User s Manual ...
Page 230: ...Appendix A T I Curves Page A 4 CM7 8 100Base T System User s Manual ...
Page 267: ...Microwave Networks CM System User s Manual PageB 37 ...
Page 268: ...Appendix B QuikLink Page B 38 CM System User s Manual ...
Page 282: ...Appendix D Alarm Codes Page D 6 5 02 05 CM 100Base T System User s Manual ...
Page 290: ...Appendix E Setting Frequency Page E 8 CM7 8 System User s Manual ...
Page 312: ...CM7 8 100Base T System User s Manual Page I 4 Microwave Networks ...