Troubleshooting
4-8
SCM4000
Operator’s Guide/Tech Ref Manual
Table 4-4: SCM4000 Encoder Parameter Errors
Error
Code
Error Message
Meaning
Suggested Operator Action
Suggested Technical Staff
Action
Status Errors
(Some internal parameter is outside of allowable limits.)
E080
COFDM/MPEG
Comm Error
•
Contact technical staff.
If problem persists, possible
hardware failure. Contact MRC
Technical Support .
Table 4-5: SCM4000 Decoder Parameter Errors
Error
Code
Error Message
Meaning
Suggested Operator Action
Suggested Technical Staff
Action
Status Errors
(Some internal parameter is outside of allowable limits.)
E120
MPEG Trans
Transport Lock Fault - There is no
valid transport stream detected by
the MPEG Decoder.
•
Ensure that the ASI channel
linked to the Decoder is
enabled and has valid data
(i.e., no errors).
•
Verify that there are no other
errors in the data channel
linked to that ASI channel.
•
Check SNR and signal
conditions to verify a strong
link is present.
•
Contact Technical staff.
If problem persists, possible
hardware failure. Contact MRC
Technical Support .
Summary of Contents for SCM4000
Page 2: ......
Page 14: ...Introduction 1 4 SCM4000 Operator s Guide This page intentionally left blank ...
Page 234: ...Repair 6 2 SCM4000 Technical Reference Manual This page intentionally left blank ...
Page 242: ...Theory of Operation 8 6 SCM4000 Technical Reference Manual This page intentionally left blank ...
Page 250: ...Glossary A 8 SCM4000 Operator s Guide Tech Ref Manual This page intentionally left blank ...
Page 274: ...Index 8 SCM4000 Technical Reference Manual This page intentionally left blank ...