background image

5 |  

 

 

Settings 

DATE AND TIME SETTING  

Press the wheel in the requested temperature display mode – the lighting will switch on. During 
a time period of the lighting press the wheel one more time. (In case the lighting function is not 
permitted on your device, press the wheel only once.) 

The accurate time will be shown on the display by big numerals. By wheel revolution set hour 
and then by pressing it confirm the setting. The setting of minutes, day, month, year and date is 
done in a similar way.  

After conforming the year by pressing the wheel you will return to the requested humidity display 
mode. 

SCREEN SAVER 

After a certain time of inactivity the measuring unit turns off the display due to the batteries´ 
energy saving. Meanwhile the measuring and control functions stay active. If the screen saver is 
active, there will be an arrow showing  towards the wheel  displayed  for a short time  and  in 
regular intervals, or the indicator located under the display blinks - depending on the set device 
parameters. 

It is possible to return to the basic state anytime by pressing the wheel. 

The screen saver function is activated only in case of permitting in the device settings.  

BATTERY CHANGE 

The device will signalize a need of battery change by showing a discharged battery icon in the 
upper part of the screen. In case the screen saver is switched on, this icon will blink 
simultaneously with the arrow in the left part of the display or the indicator light of the saver will 
blink twice.  

Batteries – two alkaline pencilling batteries AA are accessible after the plastic cover removing.  

Carefully remove the control wheel with a small, thin object (i.e. with a knife) in a following way: 

Insert the knife under the wheel from the right hand side and then pull it toward yourself gently. 

Grasp the plastic cover and by pulling the bottom part release it and then remove it.  Change 
the batteries by paying attention at the right polarity. Mount the cover. After the change set the 
accurate time and date.  

It is recommended to use lithium AA  ,,Energizer Ultimate Lithium´´ batteries  (sometimes 
labelled as Energizer L91). These batteries last longer in comparison with the usual alkaline 
batteries AA. The batteries are not accessible from another manufacturers, as Energizer 
company has got a patent at its technology.  

 Lithium batteris Energizer Ulitimate Lithium

 

Summary of Contents for Dry Precision 100

Page 1: ...DRY PRECISION 100 Humidistat User s manual ...

Page 2: ...uct specification 3 Technical parameters 3 Product control by the user 4 Settings 5 Service part Product functions 6 Parameters configuration 6 Description of configuration screens 7 Switching unit 13 Power supply 14 ...

Page 3: ...the internal memory Measured data transmission into the superior system by USB pen Lightened LCD display with big numerals TECHNICAL PARAMETERS Accuracy of relative humidity measuring 1 Control unit Accuracy of temperature measuring 1 C Adjustable correction of relative humidity display 99 Adjustable correction of temperature display 10 C Adjustable range of hysteresis of humidity switching 1 10 A...

Page 4: ...e to turn on the lighting for monitoring the measured values by pushing the wheel This does not need any setting changes The lighting function is activated only in case of permitting it in the device s settings SETTING OF THE REQUESTED TEMPERATURE Press the wheel in the requested humidity display mode The lighting will turn on During a time period of the lighting press the wheel one more time In c...

Page 5: ... wheel The screen saver function is activated only in case of permitting in the device settings BATTERY CHANGE The device will signalize a need of battery change by showing a discharged battery icon in the upper part of the screen In case the screen saver is switched on this icon will blink simultaneously with the arrow in the left part of the display or the indicator light of the saver will blink...

Page 6: ...ring is realized by an inbuilt sensor Afterwards these data are evaluated If it is important to turn on off the dehumidification a radio signal is transmitted into the switching unit In case of manual setting of the requested value the evaluation is also realized and if it is important to intervene the radio signal is sent In case of power cut of the switching unit it is detected by the measuring ...

Page 7: ...ficient of relative humidity display This coefficient is simply added to the measured humidity It is possible to monitor the corrected measuring data in the button part 3 Correction of temperature display In this window it is possible to set the correction coefficient of temperature display This coefficient is simply added to the measured temperature It is possible to monitor the corrected measuri...

Page 8: ...e hysteresis of heating switching as this is a two position regulation The hysteresis field is always located right under the requested value 6 Data measuring period This window provides a time interval setting between humidity and temperature measurings The less often setting saves battery energy but also prolongs the regulation cycle Service settings 4 Hysteresis of dehumidification control 2 Se...

Page 9: ...nstallation place In case of sufficient external alight the lighting can be turned off totally By this the batteries longevity is considerably prolonged In case of installing with the network power supply the lighting can be switched on permanently too 9 Time until display turn off This window is for time setting as long as the display is active After this time has passed the display switches to t...

Page 10: ...reen saver is not used LCD only the Arrow with a wheel icon is shown on the display LED only LED diode blinks under the display LCD LED The Arrow with a wheel icon is shown together with a LED diode blinking 12 Maximal humidity change per one measurement In this window the device sensitivity to humidity changes can be reduced by defining the max value by which the RH can be changed against the pre...

Page 11: ...this point it is possible to leave the window without any parameter changes by choosing FINISHED item After choosing the SEEK function the searching for accessible switching units get started the network addresses of found units are displayed in the window By moving the arrow to the requested address and pressing the wheel this unit can be chosen for receiving by pressing it once more the choice i...

Page 12: ...the switching unit transmits only in case the dehumidification is needed By switching this mode on the batteries longevity is prolonged however the data are periodically recorded only during the dehumidification being on Service settings 14 Transission minimizing SWITCH ON ...

Page 13: ... The dehumidification can start only after the motor s cooling down shining as red DATA TRANSMISSION INTO THE MEMORY PEN If you wish to transfer the measured and saved data for diagnosing the equipment operation please follow the following instructions Dismount the switching unit s cover by releasing 4 screws Insert the USB pen into the USB connector the green LED diode blinks and the unit identif...

Page 14: ... OVHEAT NTC sensor of compressor s overheating COM Common wire conductor of both NTC sensors The switching unit is delivered with an installed resistor 1K between FROST and COM clampers This way it is prepared for operation without NTC heat sensors In case of sensors connection it is necessary to disconnect the resistor Never disconnect the antenna from the receiver if the equipment is under press...

Page 15: ...02 0540 1 fax 031 702 0542 mobile 0903 413 764 0902 422 422 e mail microwell microwell sk Branch office Košice Kováčska 28 040 01 Košice Tel fax 055 625 25 45 Mobile 0911 454 010 e mail kosice microwell sk Please keep this user s manual in a safe place so you will find it in case of need ...