D R Y S I R E N
U s e r ´ s a n d i n s t a l l a t i o n m a n u a l
|
33
P a g e 3 3 o f 6 8
V e r s i o n : 0 1 / 2 0 1 8
SW
IM
M
IN
G
P
O
O
L
D
EH
U
M
ID
IF
IE
R
D
R
Y
S
IR
E
N
7.
INSTALLATION
–
COMPRESSOR UNIT
Compressor unit is designed for an
installation in technical room. It is a
metal box with 4 silent blocks ideally to
be installed on a wall console. This part
describes the fixation on a wall console.
Please refer to position of the
compressor unit in terms of surrounding
walls and objects.
1.
Locate the appropriate location for compressor unit. Drill 4 holes for fixation screws and fix
the wall consoles on a wall. Make sure the wall console is leveled with spirit level with max.
deviation of +/- 0.3%
197mm
max. +/-0.3%.
min. 500mm
min. 100mm
min. 300mm
min. 300mm
min. 300mm
max. 100mm