10.2
Refrigerant piping
I.
Align the center of the pipes and sufficiently tighten the flare nut by hand. Please do so for
both Suction and Discharge pipes. Suction pipe has bigger diameter. Discharge pipe has
smaller diameter.
II.
Tighten the flare nuts with torque wrench until the wrench clicks. Please make sure that the
direction for tightening follows the arrow on the wrench.
Pipe connection on compressor unit.
Pipe connection on ceiling unit.
Please review below table for torque force.
Compressor unit
Ceiling unit
12m
3m