DANGER: Be sure that the Main Manual Shut-off Valve, Combination Valve

and Burner Power Switch are turned OFF before removing any parts for service.

The venturi casting and electrodes are part of the drawer assembly which can be

removed as a unit. Remove the two back plate screws; then disconnect the elbow and pull
out the drawer assembly.

When servicing, clean venturi casting openings and electrodes. Inspect the wires and

porcelain insulators carefully for hairline cracks which might provide an electrical leak path
that could short out the ignition spark or flame signal.

Examine the electrodes for any serious corrosion or loss of metal at the tip.  The

electrode assembly is not adjustable. If the electrodes have been bent out of position, or the
spark gap is too wide (see Figure 6), the assembly is defective and must be replaced. Make
sure that the wires go to the correct electrodes and that the rubber boots are in place.

Make sure that the burner tube is properly positioned in the combustion chamber entry. It

must be set 1" short of the inside face of the combustion chamber as shown in Figures 1,2
or 8.

______________________________________________________

NOTE:

BEFORE SERVICING,  mark with a scribe line or measure opening of primary air

controlling shutter, so that it can be reset to its original position following servicing.

Cleaning of the blower wheel is usually the only service required. Need for cleaning is

indicated if the air cage assembly shows an accumulation of dust and lint, or if the character
of the flame indicates a deficiency of air.  Motor cooling air vents should also be cleaned at
this time.

The blower side plate, motor and wheel are removed as an assembly. Disconnect the

motor wires from terminal 

2

on the burner terminal strip and 

4

on the motor relay.

Disconnect the motor conduit from the control box and remove the side plate screws.

The blower wheel is equipped with a spring loaded centrifugal actuator to operate an

electrical interlock switch so as to prevent the burner from firing if the blower wheel is not
running at its operating speed. When the motor is off, the actuator spring forces the disk
against the switch plunger to push it past its operating point.  When running, the actuator
pulls the disk clear of the plunger.

To make a specific test of the interlock circuit:

1. Turn burner power 

OFF

.

2. Turn Manual Gas Cock Knob on Combination Valve to 

OFF

.

3. Disconnect the motor wire from terminal 

4

of the motor  relay to keep the motor off.

4. Turn burner power 

ON

and set the operating control to 

ON

or thermostat to call for

heat.  Check for 24V between the Electronic Control 

25V

and 

25V GND

terminals.

8

Part 2 Service

Figure 6:

Venturi Casting and Electrode Assembly

X  Venturi Casting 

and Electrodes

Part 2

Service

IX Blower Assembly 

Summary of Contents for Economite DS45B

Page 1: ...any other appli ance Installation and service must be per formed by a qualified installer service agency or the gas supplier WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas suppliers instructions If you cannot reach your gas supplier call ...

Page 2: ...ular air ducts shall not be less than 3 inches In Canada for detailed ventilation requirements refer to standard CAN 1 B149 1 or 2 and or local codes ______________________________________________________ Clean the gas utilization equipment combustion chamber heat exchanger interior and flue connections Remove all adhering tars scale dirt and soot Inspect for actual leaks and or potential leaks Ce...

Page 3: ... the burner tube is too short to reach the combustion chamber such as old fashioned gravity warm air furnace installations WARNING Burner cabinet must be mounted in orientation shown in Figures 1 and 2 Any other mountings may cause a dangerous condition and will void burner warranty and agency approvals Non standard arrangements may be available for some models consult factory for details if requi...

Page 4: ...y In no case shall the relief opening of the draft hood or barometric draft regulator be located at a point lower than the top of the highest flue passage in the equipment Gas utilization equipment requiring controlled draft may be equipped with a listed double acting barometric draft regulator installed and adjusted in accordance with the manufacturer s instructions if approved by local codes A d...

Page 5: ...igure 5 The burner gas supply piping should branch off from the main line as close to the gas meter as possible Do not connect to the bottom of a horizontal section Use new black pipe and malleable fittings free of cutting and threading burrs or defects Provide a sediment trap union and 1 8 pressure tap in piping close to burner as shown in Figure 5 Use pipe joint compound resistant to Liquid Petr...

Page 6: ...apacity spud input The burner is shipped with the primary air controlling shutter set wide open to provide a lean gas air mixture during the initial start up Do not change the combination gas valve pressure regulator setting at this time CAUTION The approximate air and gas settings described above are for initial start up only Final settings must be made in accordance with Section VIII Instruction...

Page 7: ...lization equipment must be off Then Divide by 1 000 for MBH value For PROPANE gas consult your supplier for method of determining firing rate 10 Readjust the primary air shutter to provide a quiet soft blue flame with well defined orange and yellow tips for NATURAL gas or with well defined yellow tips for PROPANE gas 11 Check the operation of the burner start and stop it several times with the the...

Page 8: ...set to its original position following servicing Cleaning of the blower wheel is usually the only service required Need for cleaning is indicated if the air cage assembly shows an accumulation of dust and lint or if the character of the flame indicates a deficiency of air Motor cooling air vents should also be cleaned at this time The blower side plate motor and wheel are removed as an assembly Di...

Page 9: ...ld gas pressure of 3 5 W C for NATURAL If pressure adjustment is required for setting capacity remove regulator cap for access to slotted adjustment screw Turning of adjustment screw counter clockwise reduces pressure clockwise increases pressure Do not adjust past the point where no change in pressure is noted NOTE Pressure setting must be made with burner running and main gas ON CAUTION When adj...

Page 10: ...Do not use this device if it gets wet It can malfunction and cause serious injury or death Replace any device that has been wet ______________________________________________________ Keep the area around the burner clear and free of combustible materials gasoline or other flammable liquids or vapors Do not obstruct burner air openings or ventilation grills for combustion air The motor features per...

Page 11: ...ER LISTED I MOTOR WILL NOT RUN OR MOTOR RUNS IN REPEATED CYCLES A Confirm 120V between strip terminals 1 and 2 and verify the circuit polarity and electrical ground between strip terminal 1 and GND B Check 24V operating control circuit 1 Between left strip terminal T and GND a No voltage transformer defective b Very low voltage circuit overloaded or transformer defective 2 Between right strip term...

Page 12: ...d steady Verify per Section VII that the spud orifice size and manifold pressure are correct b Zero erratic low or high pressure confirm that the inlet pressure to the combination valve is between 5 0 and 14 0 W C for NATURAL 11 0 to 14 0 W C PROPANE during standby and during trial for ignition c If manifold pressure is zero below 1 5 or above 3 5 W C NATURAL 10 0 W C PROPANE or erratic replace co...