13. Start and stop the burner several times to check its operation with the charging door open, and
then with it closed. Remove any temporary Door Open
bypasses installed in Step 6.
14. Test operation of any auxiliary operating and/or limit controls.
15. Load incinerator and make trial run. Confi rm that the incineration chamber pressure stays within
the range of 0 to minus 0.5″ W.C.
16.
WARNING: When the incinerator is located inside a building and a draft control is
used, check that there is no spillage of fl ue products from the draft control.
17. To shut off : Turn Burner Switch or Timer off and close Main Manual Shut -Off Valve