background image

 

MD23-104 

 

User Guide 

Mid-Continent Instruments and Avionics 

User Guide UG104, Revision 1 

 

 

January 4, 2022 

1.1 

INTRODUCTION 

The model MD23-104 battery monitor is specifically designed for the True Blue Power Gen5 
Advanced Lithium-ion batteries series. This standard 2-inch (2-¼”) panel-mounted instrument 
displays key performance and status data from either one or two Gen5 batteries. Based on Mid-
Continent Instruments and Avionics patented FLEX

TM

 Custom Function Display, this FAA and 

EASA TSO-approved instrument brings a highly capable and modern addition to the cockpit to 
display required information and provide useful supplementary functions.  

This User Guide is a supplement to the Installation Manual and Operating Instructions (IM), 
MCIA part number 9019161. The IM contains all information associated with the standard 
product, including installation procedures, product specifications, operating instructions, 
certification data, and maintenance requirements. This User Guide provides additional 
information associated with the specific features of the multifunction digital counter drum 
altimeter. It addresses product identification, electrical pinout, initial configuration setup, and in-
flight user operation.  

1.2 

PRODUCT IDENTIFICATION 

Each MD23 is comprised of certified hardware and certified software. Within the context of the 
certified software is a set of data items that can configure and customize the behavior of the unit. 
This set of data is referred to as a Custom Instrument Definition, or a CID file. The CID file for 
this instrument is pre-loaded and may be available for future updates via a standard USB flash 
drive through the programming port on the rear of the unit. 

A unique CID number has been assigned specifically to this application. The CID is identified by 
its two-digit number and an alphabetic character representing the CID version, starting with “A”.  

The identification of the hardware, software, and CID configurations are listed below. Both the 
software version and the CID can be viewed on the Introduction Screen during the first few 
seconds of applying power to the unit. This information can also be accessed on the Info page of 
the Options Menu during Flight Mode.  

 

 

 

1.3 

PRODUCT FUNCTION 

The CID identified within this User Guide is designed to function as a battery monitor for the True 
Blue Power Gen5 family of Advanced Lithium-ion Batteries. It uses ARINC 429 inputs from the 
battery to display multiple parameters such as voltage, current, state of charge, temperature and 
more. The unit can be configured upon installation to monitor one battery or two. Additional 
details can be found on a secondary status page including Remaining Life, Battery Capacity and 
detailed fault call-outs, when present. Variable thresholds and alerts, if programmed on the 
battery, will also be displayed. All ARINC data provided by the Battery 1 inputs will be re-
broadcast on the ARINC output as well.  

 

Unit Versions 

Hardware Part Number 

Software Version 

CID 

6420023-1 

1.0.2, or later

04A, or later 

Summary of Contents for MD23-104

Page 1: ... requirements are qualified to install this equipment It is a supplement to the MD23 Installation Manual and Operating Instructions p n 9019161 If further information is required please contact Mid Continent Instruments and Avionics Mid Continent Instruments and Avionics Mid Continent Instrument Co Inc dba Mid Continent Instruments and Avionics User Guide UG104 9400 E 34th Street N Revision 1 Wich...

Page 2: ...omize the behavior of the unit This set of data is referred to as a Custom Instrument Definition or a CID file The CID file for this instrument is pre loaded and may be available for future updates via a standard USB flash drive through the programming port on the rear of the unit A unique CID number has been assigned specifically to this application The CID is identified by its two digit number a...

Page 3: ...cal requirements and or statement of work and are not provided within this User Guide Connector Pinout Pin Description Function 1 Ground Power return connect to a c gnd 2 ARINC Out A Rebroadcast of ARINC In 1 data 3 ARINC Out B see pin 2 4 Dimmer Input 5 14 or 28VDC input if used 5 ARINC In 1 A ARINC In from Battery 1 6 ARINC In 2 A ARINC In from Battery 2 if used 7 Reserved 8 Reserved 9 Reserved ...

Page 4: ... user configuration item is for Battery Count Select the number of batteries that will be connected to the MD23 TBX Battery monitor 4 1 OPERATION For operation of standard unit functions including the Options Menu manual brightness control Info page and others please refer to the IM For details associated with the custom functions beyond those identified here refer to the True Blue Power Install M...

Page 5: ...o Volts Current voltage of the battery Number turns amber when under voltage or over voltage o Amps Discharge or charge current discharge current denoted as negative o Temp Internal temperature of the battery in degrees Celsius Number is red if temperature exceeds the upper limit of the battery Heater Icon represents the current state of the battery heater Icon is a gray horizontal bar if heater i...

Page 6: ...ht and select Exit to return to the Options Menu or simply wait five 5 seconds and the unit will return to the active Flight Mode display 5 1 CONFORMANCE For standard conformance items such as qualification levels and software updates please refer to the IM INSTRUCTIONS FOR CONTINUED AIRWORTHINESS No periodic scheduled maintenance or calibration is necessary for continued airworthiness of the MD23...