background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

User Manual

Online UPS

 

UPS-OL1500R | UPS-OL2200R | UPS-OL3000R 

 

 

 

 

 

 

 

 

 

 

 

 

THANK YOU 

Thank you for purchasing an online UPS product. Please read these instructions thoroughly before installing this product. 

 

 

PRODUCT FEATURES 

  Provides double-conversion (zero transfer time) online backup protection. 

  Expansion battery packs for provisioning additional runtime needs. 

  Real time reporting and notifications of battery life and when replacement is required. 

  Removable LCD display and power switch for remote convenience. 

 

May, 2016  

I-00778 Rev C 

 

Summary of Contents for UPS-OL1500R

Page 1: ...before installing this product PRODUCT FEATURES Provides double conversion zero transfer time online backup protection Expansion battery packs for provisioning additional runtime needs Real time repo...

Page 2: ...NG 7 HARDWARE INSTALLATION 8 Safety Precautions 8 Pr cautions de S curit 8 Rackmount Installation 8 Sliding Out the UPS From the Rackrail 10 INSTALLING YOUR UPS SYSTEM 11 System Block Diagram 11 Hardw...

Page 3: ...S 18 Safety Precautions 18 Pr cautions de S curit 18 Remote Control 18 Wall Mounting Instructions 18 MAINTENANCE 19 Safety Precautions 19 Pr cautions de S curit 19 Storage 19 Replacement Batteries 19...

Page 4: ...d wire prior to connecting the line wires CAUTION Do not use an improper size power cord as it may cause damage to your equipment and cause fire hazards CAUTION Wiring must be done by qualified person...

Page 5: ...ecter de la lignes ATTENTION Ne pas utiliser une taille incorrecte cordon car cela peut causer des dommages votre quipement et causer des risques d incendie ATTENTION Les travaux de c blage doit tre e...

Page 6: ...n express ment approuv s par la partie responsable de la conformit pourraient annuler l autorit de l utilisateur utiliser l quipement NOTE This equipment has been tested and found to comply with the l...

Page 7: ...unt Right Rail Left Hanging Bracket Right Hanging Bracket Rackmount Ears 2 Phone line USB communication cable Serial Interface Cable RS 232 Flat Head Screws M5x7L 8 Pan head screws M5x12L 4 Pan Head S...

Page 8: ...sport en tenant fermement les deux c t s de l unit Ne pas soulever la batterie hors de la bo te de transport tout en maintenant la face avant de l appareil car cela pourrait causer des dommages ATTENT...

Page 9: ...2L screws and 2 screws for both front and back and for each rail Tighten all screws 6 Slide hanging brackets on the UPS into the rails mounted in the rack with the front of the unit facing you Secure...

Page 10: ...the Rackrail 1 Turn off and unplug the unit 2 The UPS is secured from being pulled out of the rack any further than its mid length by a safety lock mechanism Use both hands to hold the UPS and press t...

Page 11: ...t unplug some equipment from the outlets first Make sure your equipment carries a load current within the unit s safe range See Technical Specifications on page 22 for more information 6 This UPS is e...

Page 12: ...port provides communication between the UPS and the computer The UPS can control the computer s shutdown during a power outage through this connection while the computer can monitor the UPS and alter...

Page 13: ...ry Mode This state is enabled whenever utility power is disengaged Bypass Mode UPS is operating in Bypass Mode This state is enabled when the UPS detects an overload DC bus Bus Fault inverter High O P...

Page 14: ...Output Voltage O P Freq XX XHz Displays the Output Frequency I P Volt XXX XV Displays the Input Voltage I P Freq XX XHz Displays the Input Frequency O P Load XXX Displays the Output Load as a Percent...

Page 15: ...olumn of LCD screen 6 Press the and buttons to scroll through the different parameters 7 Press the ENTER button to select the parameter you want to change You may be prompted to save the selection if...

Page 16: ...req 60Hz Converter OFF Sets the UPS converter to OFF 50Hz or 60Hz Screen Saver Disable 1 Minutes 5 Minutes 5 minutes When enabled sets the LCD screen saver to initiate after either 1 or 5 minutes of i...

Page 17: ...LCD screen and the unit will perform a manual battery test Graphical Load Battery Capacity Display 1 Press the ESC button to return to UPS Status 2 Press the and buttons to scroll to the LOAD and BAT...

Page 18: ...e Remote Control 1 Turn off and unplug the unit 2 Remove the multifunction LCD module by unscrewing the right panel separating it from the UPS and gently lifting the LCD module out Reinstall the right...

Page 19: ...cha nes montres bracelets et bagues ATTENTION Ne pas ouvrir ni mutiler la batterie l lectrolyte lib r est nocif pour la peau et les yeux ATTENTION Pour viter un choc lectrique teindre et de d brancher...

Page 20: ...out slowly and then put the new battery tray back into the compartment 5 Fasten back the connectors on the battery retaining cover Then insert the battery connectors and tighten the screws of battery...

Page 21: ...e information about Middle Atlantic Product s Battery Replacement Program MAP UPS or EBPR Part Number Description Compatible Expansion Battery Packs UPS OLRBP 1 UPS OLRBP 2 UPS OLRBP 3 UPS OLRBP 4 UPS...

Page 22: ...it Protection UPS Output Cut off Immediately or Input Fuse Circuit Breaker Protection Battery Specifications 3 12V 9AH 6 12V 9AH Recharge Time Typically 5 hours for 0 100 Capacity 4 hours for 0 90 Cap...

Page 23: ...ormation about Middle Atlantic Product s Battery Replacement Program EPO OFF Missing the EPO connection Check the EPO connection Wiring Fault Line and neutral wires are reversed Have a qualified elect...

Page 24: ...OTHER WARRANTIES OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THE MAXIMUM EXTENT PERMITTED BY APP...

Reviews: