INSTALLATION & OPERATION MANUAL, ELECTRIC COUNTER PAN STEAMERS, EPXN-3, EPXN-5
8.0 TROUBLESHOOTING
(Continued)
Buzzer
If the buzzer does not sound at the termination of the operator-selected timer setting (timer dial
returned to “0 - Minute” position), the fault may be a defective buzzer. Buzzer operation is
verified using an AC voltmeter at buzzer coil connections with input power on and selector
switch and coinciding timer dial set at the “0 - Minute” position. If voltage is 240 volts, the fault
is in the buzzer, which must be replaced. If 240 volts is not present, the fault is in the wiring or
control components (timer or selector switch).
Wiring
WARNING: Disconnect the power supply to the appliance before
cleaning or servicing.
Using an ohmmeter, wiring continuity between the connections shown on the wiring diagram is
readily verified. This is best done in stages, removing only those wires required for each
continuity check. As each lead is replaced, it should be checked for evidence of corrosion, and
cleaned if necessary. All leads must be tightly attached so as to provide a good electrical
connection.
Door Gasket
Check gasket for cuts and replace if necessary.
Door Gasket Replacement
The cooking compartment door gaskets are made of a silicone-type rubber material that is very
durable but subject to wear during normal operation. Should the gasket leak replace it.
1. Open the cooking compartment door.
2. Remove the six or eight screws from the gasket plate in the door panel assembly.
3. Remove the gasket plate and the door gasket from door panel.
Part No. 10234R3
22
2020-02-24