·  When the water level of the bottom tray reaches a 
   predetermined level, the unit beeps 8 times, the 
   digital display area shows "P1" . At this time the air 
   conditioning/dehumidification process will 
   immediately stop. However, the fan motor will 
   continue to operate(this is normal). Carefully move 
   the unit to a drain location, remove the bottom drain 
   plug and let the water drain away. Reinstall the bottom 
   drain plug and restart the machine until the "P1" 
   symbol disappears. If the error repeats, call for service.

NOTE: Be sure to reinstall the bottom drain plug firmly 
to prevent leakage before using the unit.

When the water drainage function is not in use, 
keep the upper and the lower drain plug firmly to 
the unit to get rid of choking. When the drain plug 
is not in use, keep it carefully to prevent children 
from choking. 

NOTE: Make sure the hose is secure so there are no 
leaks. Direct the hose toward the drain, making sure 
that there are no kinks that will stop the warter flowing.
Place the end of the hose into the drain and make sure 
the end of the hose is down to let the water flow 
smoothly. When the continuous drain hose is not used,  
ensure that the drain plug and knob are installed firmly 
to prevent leakage.

Safety Precautions

Maintenance

·  Always unplug the unit before cleaning or servicing.
·  DO NOT use flammable liquids or chemicals to clean the unit. 
·  DO NOT wash the unit under running water. Doing so causes electrical danger.
·  DO NOT operate the machine if the power supply was damaged during cleaning. A damaged 
   power cord must be replaced with a new cord from the manufacturer.

Upper filter
(take out)

lower filter B

(take out)

lower filter A
(Press the grill down 
slightly and pull the 
lower filter A out at 
the same time)

            CAUTION  
DO NOT operate the unit without filter 
because dirt and lint will clog it and reduce 
performance.

Remove the air filter 

Maintenance Tips

·  Be sure to clean the air filter every 2 weeks for 
   optimal performance.
·  The water collection tray should be drained 
   immediately after P1 error occurs, and before 
   storage to prevent mold. 
·  In households with animals, you will have to 
   periodically wipe down  the grill to prevent 
   blocked airflow due to animal hair. 

Clean the unit using a damp, lint-free cloth and mild detergent. Dry the unit with a dry, lint-free 
cloth. 

 
 
 

Summary of Contents for 21615024

Page 1: ...ice la client le est disponible pour vous aider En cas de probl me avec votre achat ou pour obtenir plus d informations propos de ce produit veuillez composer notre num ro sans frais CONSERVEZ CE GUID...

Page 2: ...ore the unit when not in use Preparation Design Notice Ambient Temperature Range For Unit Operating Exhaust Hose Installation Choosing The Right Location Tools Needed Accessories Window Installation K...

Page 3: ...e and injury or property damage Make sure that the outlet you are using is grounded and has the appropriate voltage The power cord is equipped with a three prong grounding plug to protect against shoc...

Page 4: ...ensure that they do not play with the appliance Children must be supervised around the unit at all times If the supply cord is damaged it must be replaced by the manufacturer its service agent or simi...

Page 5: ...anything other than your fingers Do not remove any fixed covers Never use this appliance if it is not working properly or if it has been dropped or damaged Do not operate or stop the unit by insertin...

Page 6: ...ol are subject to change without prior notice Cool 17 35 C 62 95 F Dry Heat pump heat mode Heat electrical heat mode 13 35 C 55 95 F 5 30 C 41 86 F control panel handle both sides horizontal louver bl...

Page 7: ...use damage to the unit 30cm 30cm 12inch 12inch 50cm 19 7 inch Energy Rating Information The unit with 3 meters extended exhaust duct is running by using 2 exhaust ducts Diameter 150mm Length 1 5m Diam...

Page 8: ...2 pc Foam Seal B Adhesive 2 pc Foam Seal C Non adhesive NOTE Slight variations in design may occur Window Installation Kit Unit adaptor Window slider adaptor Exhaust hose Exhaust hose assembly Hook H...

Page 9: ...the non adhesive foam seal C strip to match the width or height of the window Insert the seal between the glass and the window frame to prevent air and insects from getting into the room 2 Insert the...

Page 10: ...slider 2 Screws Security Bracket NOTE To ensure proper function DO NOT overextend or bend the hose Make sure that there is no obstacle around the air outlet of the exhaust hose in the range of 500mm...

Page 11: ...not contain some indicators or buttons The actual shape shall prevail Indicator Function Indicator Function HIGH fan speed light MED fan speed light LOW fan speed light ION light SLEEP light Degrees C...

Page 12: ...n repeats call for service E4 Display panel communication error Fan Ion button Control the fan speed Press to select the fan speed in four steps LOW MED On some models HIGH and AUTO The corresponding...

Page 13: ...by 1 C 1 F or 2 F 30 minutes The temperature will then increase cooling or decrease heating by another 1 C 1 F or 2 F after an additional 30 minutes This new temperature will be maintained for 7 hour...

Page 14: ...in If the unit does not receive the Follow Me Temp Sensing signal during any 7 minutes interval the nit will exit the Follow Me Temp Sensing mode NOTE This feature is unavailabe under FAN or DRY mode...

Page 15: ...ain and make sure the end of the hose is down to let the water flow smoothly When the continuous drain hose is not used ensure that the drain plug and knob are installed firmly to prevent leakage Safe...

Page 16: ...ressing ON OFF button P1 Error Code In COOL mode room temperature is lower than the set temperature Reset the temperature The Water Collection Tray is full Turn off the unit drain the water from the W...

Page 17: ...nment Signal Receiving Range RG57H2 B BG C EF M Remote Control Specifications O O O O 5 C 60 C 23 F 140 F Remote controller lllustration CAUTION INGESTION HAZARD Contains small batteries Keep out of r...

Page 18: ...Remote controller lllustration...

Page 19: ...Remote controller lllustration...

Page 20: ...Remote controller lllustration...

Page 21: ...Remote controller lllustration...

Page 22: ...Remote controller lllustration...

Page 23: ...Remote controller lllustration...

Page 24: ...Remote controller lllustration...

Page 25: ...Remote controller lllustration...

Page 26: ...Remote controller lllustration...

Page 27: ...Remote controller lllustration...

Page 28: ...Remote controller lllustration...

Page 29: ...Remote controller lllustration...

Page 30: ...Air Conditioner Limited Warranty Air Conditioner Limited Warranty...

Page 31: ......

Page 32: ......

Reviews: