Service Manual_2018-V2.0
25
8.7 Compressor case
Compressor and the cooling system pipe
Fuse
1
)
Disconnect the fuse connector.
2
)
Cut off the band which fixes the fuse.
3
)
Separate the fuse and the evaporator.
*
Don’t break the welding of the evaporator in case that
only the fuse needs to be replaced.
Defrost sensor
The defrost sensor is located on top of the evaporator.
1
)
Disconnect the connector of defrost sensor
2
)
Cut off the band which fixes the sensor.
3
)
Separate the sensor and the evaporator.
*
Don’t break the welding of the evaporator in case that
only the sensor needs to be replaced.
Defrost heater
The defrost heater is located at bottom of the evaporator.
1
)
Disconnect the connector of defrost heater.
2
)
Cut off the band which fixes the defrost heater.
3
)
Take off the defrost heater from the evaporator.
*D
on’t break the welding of the evaporator in case that
only the defrost heater needs to be replaced.
Evaporator in refrigerating chamber
None
Components on the evaporator
Defrosting fuse
None
Defrost sensor
None
Defrost heater
None
Summary of Contents for 22031020003641
Page 5: ...Service Manual_2018 V2 0 5 1 Significant update notes None...
Page 18: ...Service Manual_2018 V2 0 18 6 5Main control board schematic diagram...
Page 20: ...Service Manual_2018 V2 0 20 7 3 Circulating route of cooling air...
Page 38: ...Service Manual_2018 V2 0 38 12 Troubleshooting Method 12 1 No cooling Air cooling Electronic...
Page 39: ...Service Manual_2018 V2 0 39 12 2 No working of compressor 12 3 Inside frosting no defrosting...
Page 40: ...Service Manual_2018 V2 0 40 12 4 Inside frosting no defrosting Maintenance guidelines...
Page 41: ...Service Manual_2018 V2 0 41 12 5 Light is not on 12 6 Fan failure...
Page 42: ...Service Manual_2018 V2 0 42 12 7 Defective defrost circuit 12 8 Noise...
Page 43: ...Service Manual_2018 V2 0 43 12 9 Air duct not operated electronically None...
Page 44: ...Service Manual_2018 V2 0 44 13 Figures and details of repair parts See this section in the TSP...