Page 21
Operating
Instructions
WAIT 3 MINUTES BEFORE RESUMING OPERATION
After the unit has stopped, it can not be restarted
operation in the first 3 minutes. This is to protect the
unit. Operation will automatically start after 3 minutes.
AIR FLOW DIRECTION ADJUSTMENT
The louver can be adjusted automatically. Adjust the
air flow direction automatically:
· When the Power is ON, the louver opens fully.
· Press the SWING button on the panel or remote
controller to initiate the Auto swing feature. The
louver willl swing up and down automatically.
· Please do not adjust the louver manually.
POWER MANAGEMENT feature(On some models)
Under cooling operation, when the ambient
temperature is lower than the setting temperature for
a period of time, the unit will be automatically operate
power management feature. The compressor and fan
motor stop. When the ambient temperature is higher
than the setting temperature, the unit will be
automatically quit the power management feature.
The compressor and (or) fan motor run.
Water drainage
· During dehumidifying modes, remove the upper
drain plug from the back of the unit, install the drain
connector(5/8" universal female mender) with 3/4"
hose(locally purchased). For the models without
drain connector, just attach the drain hose to the
hole. Place the open end of the hose directly over the
drain area in your basement floor.
MODEL A
MODEL B
Remove the
upper drain plug
√
Continuous
drain hose
Remove the
upper drain plug
√
Continuous
drain hose
· During heating pump mode, remove the lower drain
plug from the back of the unit, install the drain
connector (5/8" universal female mender) with 3/4"
hose(locally purchased). For the models without drain
connector, just attach the drain hose to the hole.
Place the open end of the Hose adaptor directly over
the drain area in your basement floor.
that there are no kinks that will stop the warter flowing.
Place the end of the hose into the drain and make sure
the end of the hose is down to let the water flow
smoothly.(See Figs with . Do never let it up.(See Figs
with ). When the continuous drain hose is not used,
ensure that the corresponding drain plug and knob
are installed firmly to prevent leakage.
NOTE: Make sure the hose is secure so there are no
leaks. Direct the hose toward the drain, making sure
√
X
MODEL B
√
drain hose
adaptor
Continuous
drain hose
Remove the
lower drain plug
MODEL A
√
drain hose
adaptor
Continuous
drain hose
Remove the
lower drain plug
X
drain hose
adaptor
Press the power
cord buckle into
the rear cover.
drain hose
adaptor
√
delivery lift <1.8m
MODEL A1
Continuous
drain hose
Remove the
lower drain plug
· (For model A1)During heating pump mode, remove
the lower drain plug from the back of the unit, install
the drain connector(5/8" universal female mender)
with 3/4" hose(locally purchased). Carefully move the
unit to a drain location, and let the water drain away.
Note: Make sure the drain hose is lower than the
bottom tray drain outlet.
· When the water level of the bottom tray reaches a
predetermined level, the unit beeps 8 times, the
digital display area shows "P1" . At this time
the air conditioning/dehumidification
process will immediately stop. However,
the fan motor will continue to operate
(this is normal). Carefully move the unit
to a drain location, remove the bottom
drain plug and let the water drain away. Reinstall the
bottom drain plug and restart the machine until the
"P1" symbol disappears. If the error repeats, call for
service. NOTE: Be sure to reinstall the bottom drain
plug firmly to prevent leakage before using the unit.