8. Electronic function
8.1 Abbreviation
T1: Indoor ambient temperature
T2: Pipe temperature of indoor heat exchanger
Ts: Set temperature
8.2 Display function
8.2.1 Icon explanation on indoor display board:
Run indicator
Flash at 0.5Hz when the unit is standby. Illuminate when the unit is turned on
.
Auto indicator
This indicator illuminates when the air conditioner is in AUTO operation.
Timer indicator
This indicator illuminates when TIMER is set ON/OFF.
Defrost Indicator
This indicator illuminates when the air conditioner starts defrosting automatically or when the
warm air control feature is activated in heating mode
TURBO operation display
Illuminated when select TURBO function in cooling operation or in heating operation.
TEMPERATURE indicator
Usually it displays the temperature settings. When change the setting temperature, this
indicator begins to flash, and stops 20 seconds later. It displays the room temperature when
the air conditioner is in FAN only operation, and the range of that is 0~50
℃
. It will also
display the error codes when malfunction or protection happen.
8.2.2 LED display control function.
Pressing “LED display” button on remote controller will turn off all displays on indoor unit, while pressing
once again, all displays will resume.
Summary of Contents for 9V SERIES
Page 13: ...11 4 Refrigerant Cycle Diagram Cooling only Heat pump mode...
Page 14: ...12 5 Wiring Diagram 5 1 Indoor Unit Cooling only...
Page 15: ...13 Cooling Heating...
Page 16: ...14 5 2 Outdoor Unit Smaller than 18K model Cooling only...
Page 17: ...15 Cooling Heating...
Page 18: ...16 For 18 K model Cooling only...
Page 19: ...17 Cooling Heating...