38
E2
Zero-Crossing Error
E3
Indoor fan speed out of control
E4
Over current protection occurs 4 times
E5
Open or short circuit of Room temperature sensor
E6
Evaporator temperature sensor open or short circuit
9.2 Diagnosis and Solution
9.2.1 E1 (EEPROM parameter error) error diagnosis and solution
Replace indoor PCB
Shut off the power supply and turn on it 5s later
The problem comes out again
Is the EEPROM chip plugged in indoor PCB well?
NO
Correct the connection
Replace the main PCB of indoor unit