“timer off” function. And when reaching the
setting time, the timer LED will be off and the
AC running mode has not been changed.
8.4.7.7 The setting time is relative time.
8.4.7.8 The AC will quit the timer function when
it has malfunction.
8.4.8 Economy function
8.4.8.1 The sleep function is available in
cooling, heating or auto mode.
8.4.8.2. Operation process in sleep mode is as
follow:
When cooling, the setting temperature rises 1
℃
(be lower than 30
℃
) every one hour, 2 hours
later the setting temperature stops rising and
the indoor fan is fixed at low speed.
When
heating,
the
setting
temperature
decreases 1
℃
(be higher than 17
℃
) every one
hour, 2 hours later the setting temperature
stops rising and indoor fan is fixed at low speed.
(Anti-cold wind function has the priority).
8.4.8.3 Operation time in sleep mode is 7 hours.
After 7 hours the AC quits this mode and turn
off.
8.4.8.4 Timer setting is available
8.4.9 Auto-Restart function
The indoor unit is equipped with auto-restart
function, which is carried out through an
auto-restart module. In case of a sudden power
failure, the module memorizes the setting
conditions before the power failure. The unit will
resume the previous operation setting (not
including swing function) automatically after 3
minutes when power returns.
If the memorization condition is forced cooling
mode, the unit will run in cooling mode for 30
minutes and turn to auto mode as 24
℃
setting
temp.
If AC is off before power off and AC is required
to start up now, the compressor will have 1
minute delay when power on. Other conditions,
the compressor will have 3 minutes delay when
restarts.
8.4.10 Refrigerant Leakage Detection
With this new technology, the display area will
show
“EC” when the outdoor unit detects
refrigerant leakage.
8.4.11 Louver Position Memory Function
When starting the unit again after shutting down,
its louver will restore to the angle originally set
by the user, but the precondition is that the
angle must be within the allowable range, if it
exceeds, it will memorize the maximum angle
of the louver. During operation, if the power fails
or the end user shuts down the unit in the turbo
mode, the louver will restore to the default
angle.
8.4.12 8
℃
Heating(optional)
In heating operation, the preset temperature of
the air conditioner can be as lower as 8
℃
,
which keeps the room temperature steady at
8
℃
and prevents household things freezing
when the house is unoccupied for a long time in
severe cold weather.
8.4.13 Self clean(optional)
For heat pump models which are provided with
this function, after running in cooling or drying
mode, if
the user press “Self Clean” button on
remote controller, firstly, indoor unit runs in fan
only mode for a while, then low heat operation
and finally runs in fan only again. This function
can keep the inside of indoor unit dry and
prevent breeding of mold.
8.4.14 Follow me
1) If the indoor PCB receives the signal which
results from pressing the FOLLOW ME button
on remote controller, the buzzer will emit a
sound and this indicates the follow me function
is initiated. But when the indoor PCB receives
signal which sent from remote controller every
3 minutes, the buzzer will not respond. When
the unit is running with follow me function, the
PCB will control the unit according to the
temperature from follow me signal, and the
temperature collection function of room