Service Manual_2018-V2.0
30
11. Compressor
1.1
11.1Compressor on and off Control specifications
When one of the following conditions is
met, the compressor stops:
1)
Tr ≤ Trt
;
2)
The compressor runs continuously for more than 3 hours (Stop 5 minutes);
1.2
When all the following conditions are met, the compressor starts up:
1)
Tr ≥Trk;
2) Compressor downtime is more than 5min.
★
When 1.1 and 1.2 are not satisfied, the compressor maintains the original state
Summary of Contents for COMBI HD-273FN
Page 5: ...Service Manual_2018 V2 0 5 1 Significant update notes None...
Page 20: ...Service Manual_2018 V2 0 20 7 2 Special soldering position...
Page 31: ...Service Manual_2018 V2 0 31 12 Troubleshooting Method 12 1Not cooling...
Page 34: ...Service Manual_2018 V2 0 34 12 6 Light is not on...
Page 35: ...Service Manual_2018 V2 0 35 12 7 Noise...
Page 36: ...Service Manual_2018 V2 0 36 13 Figures and details of repair parts See this section in the TSP...