34
INSTALLATION OF THE CONDENSATION DRAINAGE HOSE
· When installing an extension of the condensation drainage hose, insulate the connecting part with a safety pipe and do
not let the hose hang loosely.
· To install the condensation drainage hose on the left, install it as shown in the illustration. Bend the connecting tube to
no more than 43 mm from the bending point to the straight line.
· Fasten the end of the condensation drainage hose.
· Connect the condensation drain on the indoor air conditioning unit tightly to the supplied condensation drainage hose.
Pipe cover
left
Cable connection
To the outdoor unit
Power supply
Pipes with
insulation
INSTALLATION OF THE INDOOR UNIT
caution
· First, connect the indoor unit, then the outdoor unit.
· Carefully bend and align the coolant lines.
· Do not let the coolant lines protrude from the back of the indoor unit.
· Make sure that the condensation drainage hose is not loose.
· Insulate both coolant lines at the connections.
· Always tie the condensation drainage hose under the coolant line.
· All lines must be placed inside of the indoor unit and may not protrude.
· Make sure that the pipes on the back of the indoor unit do not leak.
· Make sure that the condensation drainage hose is placed at the lowest point of the insulation package.
The condensation drainage hose must remain separate from the connecting pipe and cable to prevent condensate from
overflowing.
· Please do not cross the power cord with any other cables.
· Please let the condensation drainage hose hang down in a slope so that the condensate can drain without a problem.
· Insert the pipe through the bore into the indoor unit.
· Tighten the upper clamp on the back of the indoor unit at the upper hook of the installation plate and move the indoor
unit from one side to the other to make sure that it is hooked securely.
· To simplify the connection of the pipe, lift the indoor unit away from the wall using padding, a screwdriver, or similar tool.
When the connection is complete, remove the padding, screwdriver, or similar tool.
· Install the lower part of the indoor unit on the wall. Then move the indoor unit sideways and vertically to ensure that
is hooked securely.
Indoor unit
Connecting pipe
43 mm
Upper hook
Lower hook
Damping material