2. PRODUCT INTRODUCTION

2.1  Technical Performance Parameters

FP-67WTR380WMTH-B1

FP-67WTR380WMTM-W1

Model

Rated

Rated

Rated

Voltage

Rated  Frequency

 Power

Current

Dia. Of  Wire Cord

 

 

Circuit Breaker

R ated 

Minimum Flow R ate

Minimum  Pressure

Pressure

Pressure

Maximum 

Protection  Class

Waterproof

 

Class

Product Size ( WxHxD)

Knob  Quantity

3800W

0

17A

4mm²

≥20A

0

17A

3800W

4mm²

≥20A

I

230V~

60 Hz

0 MP a

1.2 Liters/minute

 

0.03 MPa (4.4 psi)

0.3 MPa (43.5 psi)

 

IP 25

200×400×95 mm

1

4

Summary of Contents for ECOHEAT FP-67WTR380WMTH-B1

Page 1: ...ter Heater ECOHEAT SERIES Rated Voltage 230V Rated Power 3800W Frequency 60Hz Weight 1 95 2 25kg Dimensions WxHxD 200x400x95mm FP 67WTR380WMTM W1 FP 67WTR380WMTH B1 version 000 ph midea com USER S MANUAL ...

Page 2: ... 6 Troubleshooting 12 Sincerely thank you for selecting our electric water heater Please read this manual carefully before use correctly grasp the methods for installation and use of this electrical water heater to make full use of its superior performance Please do preserve the instruction manual for future reference ...

Page 3: ...r ahead of time to protect the water heater against possible damage Inspect the built in ELCB once a month to avoid hazards to users such as damage to property serious injury or death Do not cut off power supply before maintenance Any maintenance or adjustment of product by a non professional is highly prohibited The damaged power cord must be replaced by good one provided by the manufacturer and ...

Page 4: ...sually connected for convenience You only need to connect the E1 to the ground terminal and E2 P2 to the auxiliary electrode steel bar in the soil ground If there is no soil to drill the steel bar in you can connect P2 E2 to the neutral terminal fire hoses or floors which can be considered as the ground resistance Then press the POWER button select the appropriate test range if not clear about the...

Page 5: ...Rated Frequency Power Current Dia Of Wire Cord Circuit Breaker R ated Minimum Flow R ate Minimum Pressure Pressure Pressure Maximum Protection Class Waterproof Class Product Size WxHxD Knob Quantity 3800W 0 17A 4mm 20A 0 17A 3800W 4mm 20A I 230V 60 Hz 0 MPa 1 2 Liters minute 0 03 MPa 4 4 psi 0 3 MPa 43 5 psi IP25 200 400 95 mm 1 4 ...

Page 6: ...inless steel circlip Temperature sensor Marker for wateroutlet Water outlet Red Blue FOR FP 67WTR380WMTM W1 FOR FP 67WTR380WMTH B1 Terminal block Silicon control Flow sensor Marker for water inlet Water inlet Wire pressing board Thermal cut out Main control board Heating elements assembly Stainless steel circlip Temperature sensor Marker for wateroutlet Water outlet Red Blue Indicator light board ...

Page 7: ...t Indicator Light Main Control Board Terminal Block Key board Silicon Control Mutual inductor 11 Flow Sensor Mutual inductor Silicon Control Temperature Sensor Heating Elements Thermal Cut Out Indicator Light Main Control Board Terminal Block Key board Flow Sensor L N CN6 5 6 4 7 9 1 2 N PE L G T1 T2 3 8 10 N L RL2 RL1 CN1 5 6 4 7 9 3 10 1 2 N PE L G T1 T2 8 11 ...

Page 8: ...t the Main Switch Knob and Power Knob to make it free Remove the front plate gently Gash the middle of the film of the power cord jacket with a sharp knife in order to put into power lines Tighten the wire pressing plate with screws to primary position ensure that the power cord not be pulled out more than 60N Remove the power cord wire pressing plate and keep the screws Insert by turning the powe...

Page 9: ...the screws on the top and ensure certain distance between screw head and wall See Fig 1 Mount the unit on the wall and tighten with two screws at bottom connect the wires and install top cover with the screws Determine installation position of the unit according to length of power cord position of circuit breaker Distance between bottom and floor should be 1 6m 3 4 Plumbing Connection A flexibe sh...

Page 10: ...ter must be used when installing the unit Blue marker stands for water inlet red marker stands for water outlet Do not apply excessive torque force to avoid damaging the water heater NOTE A dedicated power cord should be used for this unit After connecting to electric circuit please check the earth condition and make sure the earth resistance is 4Ω After all the plumbing connections are finished o...

Page 11: ... won t cancel leakage testing The ELCB POWER indicator lights will flicker meaning the water heater has problems and cannot be used All buttons won t work there will be no heating and the pump will not function The pump will be on as the default setting when the product is used the first time and can be turned off by pressing the PUMP button which turns this function on and off When the electricit...

Page 12: ...out of the shower head Outlet water temperature is sometimes hot or cold Pressure can t be increased 1 The thermal sensor cut off the circuit 2 Heating element is broken EARTH ELCB and POWER indicator lights flicker at the same time POWER indicator light flickers 5 MAINTENANCE DECLARATION this water heater can only be maintained by authorized service personnel Incorrect installation and use may ca...

Page 13: ...ation please visit our website www midea com ph Customer Care 02 863 55 22 Landline 0917 863 5522 Viber SMS customercare midea com ph Email 1 800 10 863 5522 Toll free Monday Sunday 8 00am 8 00pm A quality product of ...

Reviews: