background image

When the air filter is to be 
removed, do not touch the metal 
parts of the unit.

It may cause an injury.

Do not clean unit when power is on 
as it  may  cause  

fire  

and  

electric

 

shock,

it may cause an injury.

Operation with windows opened 
may cause wetting of indoor and 
soaking of household furniture.

When the unit is to be cleaned, 
switch off, and turn off the circuit 
breaker.

Use caution when unpacking and 
installing. Sharp edges could cause injury.

Do not clean the air conditioner 
with water.

Water may enter the unit and 
degrade the insulation. It may 
cause an electric shock.

This could injure the pet or plant.

It may cause electric shock and 
damage.

Do not put a pet or house plant 
where it will be exposed to direct 
air flow.

Ventilate the room well when
used together with a stove, etc.

An oxygen shortage may occur.

Do not use this air conditioner to 

preserve precision devices, food,

pets, plants, and art objects.It may 

cause deterioration of quality, etc. 

It may cause failure of product or 

fire.

Do not use for special purposes.

If water enters the unit, turn the unit off at the power 
outlet and switch off the circuit breaker. Isolate 
supply by taking the power-plug out and contact a 
qualified service technician.

It may cause failure of appliance 
or accident.

Appearance may be deteriorated 
due to change of product color or 
scratching of its surface.

If bracket is damaged, there is 
concern of damage due to falling 
of unit.

There is danger of fire or electric 
shock.

Operation without filters maycause 

failure.

It contains contaminants and 

could make you sick.

Stop operation and close the 
window in storm or hurricane.

Do not use strong detergent 
such as wax or thinner but use 
a soft cloth.

Ensure that the installation bracket of the 
outdoor appliance is not damaged due 
to prolonged exposure.

Hold the plug by the head of the 
power plug when taking it out.

Turn off the main power  
switch when not  sing the
unit for a long time.

u

Always insert the filters securely. 
Clean filter once  every  two  weeks.

Do not place heavy object on the power
cord and ensure that the cord is not 
compressed.

Do not drink water drained 
from air conditioner.

   This appliance is not intended for use by persons 
   (including children) with reduced physical ,sensory 
   or mental capabilities or lack of experience and 
   knowledge, unless  they  

have  

been  

given  

supervision

 

   or instruction concerning use of the appliance by 
   a person responsible for their safety. 
   Children should be supervised to ensure that they 
   do not play with the appliance. 
   If the supply cord is damaged, it must be replaced 
   by the manufacturer, its service agent or similarly 
   qualified persons in order to avoid a hazard.
   
   
   

CAUTION

2

CAUTION

Do not place obstacles around 
air-inlets or inside of air-outlet.

   
   
   The appliance shall be installed in accordance 
   with national wiring regulations.
   Do not  operate  your  air  conditioner  in  a  wet  room

     such  as  a  bathroom  or  laundry  room.
    The appliance with electric heater shall  have  at

       least 1  

meter  

space  

to  

the  

combustible materials.

    Contact the authorised service technician for 

   repair or maintenance of this unit.
   Contact the authorised installer for installation 
   of this unit.
   
   

IMPORTANT SAFETY INSTRUCTIONS

Summary of Contents for EWK06CW5

Page 1: ...210 285 80g...

Page 2: ...al carefully and keep it for future reference WINDOW TYPE ROOM AIR CONDITIONER TABLE OF CONTENTS Installation Instructions 18 4 17 Normal Sounds Important Safety Instructions 1 3 Troubleshooting Tips...

Page 3: ...eat generation excess It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause fire It may cause explos...

Page 4: ...ters maycause failure It contains contaminants and could make you sick Stop operation and close the window in storm or hurricane Do not use strong detergent such as wax or thinner but use a soft cloth...

Page 5: ...he window is a triple track type with a screen panel included remove the screen completely before installation Be sure the air conditioner has been securely and correctly installed according to the in...

Page 6: ...s manual are for explanation purpose only The air conditioner you have may be slightly different The actual shape shall prevail NOTE 4 INSTALLATION INSTRUCTIONS NOTE The unit you purchased may be look...

Page 7: ...in these instructions when installing this air conditioner BEFORE YOU BEGIN Do not under any circumstances cut or remove the third ground prong from the power cord CAUTION Do not change the plug on th...

Page 8: ...models only Fig C NOTE The top rail hardware and the Fig A Fig B and Fig C are not applicable to the units more than 10000Btu h Before installing unit the top rail must be assembled on the unit For 10...

Page 9: ...against the window sill Fig 5A and Fig 5B Carefully close the window behind the top rail of the unit Fig 5A If storm window blocks AC see Fig 11 NOTE Top Rail Bottom Rail Top left Top right Fig 4 Wood...

Page 10: ...in the frame lock and frame extensions into the windows sash as shown Fig 8B Fig 8A Fig 8B C To secure lower sash in place attach right angle sash lock with 3 4 19mm or 1 screw as shown Fig 9 2 12 7mm...

Page 11: ...rm grip on air conditioner raise sash and carefully remove Be carefully not to spill any remaining water while lifting unit from window Store parts WITH air conditioner Board thickness as required for...

Page 12: ...ils Save Carton and these Installation Instructions for future reference The carton is the best way to store unit during winter or when not in use NOTE Preliminary Instructions Do the following before...

Page 13: ...nch Long Flat Head Bolt and Locknut Sill Angle Bracket Long hex head locking screw for top angle side retainer 5 16 inch Long 2 ea 7 1 4ea 2ea 2 10 Foam insert 2 Window sash seal foam 1 A Window Mount...

Page 14: ...en Allow leg to slide freely Screws will be tightened after section 6 4 Place Cabinet in window 1 Open window and mark center of window inner sill as shown Fig 11 2 Place cabinet in window with bottom...

Page 15: ...d Window Filler Panels 1 Carefully raise window to expose filler panel locking screws Loosen screws so filler panels slide easily 2 Extend panels to fill window opening completely Tighten locking scre...

Page 16: ...gh the hole in the top leg of each window filler panel and into the window sash Fig 18A and Fig 18B Connect with one 3 4 or 1 2 long hex head screw 8 1 Trim sash seal to fit window width Insert into s...

Page 17: ...els In order to minimize air leaks and ensure optimal insulation it is necessary to install the included R1 hardware to the side curtain Follow the instructions below Step 1 After the unit is installe...

Page 18: ...d except a wood frame shims and 10 wood screws 10 1 long minimum Select a wall surface that 1 does not support major structural loads such as the frame construction at ends of windows and under truss...

Page 19: ...versized to eliminate distortion See Fig 8 Remember to maintain proper slope as described in Step 3 Fig 8 OPTIONAL NOTE Caulking and installation of trim on interior wall may be done You can buy wood...

Page 20: ...may be heard due to refrigerant passing through evaporator during normal operation Pinging or Switching Droplets of water hitting condenser during normal operation may cause pinging or switching soun...

Page 21: ...onal Louvers Lever Air Direction The louvers will allow you to direct the air flow Left or Right throughout the room as needed Move the Levers from side to side until the desired Left Right direction...

Page 22: ...kwise for higher cool settings Higher cool settings will provide lower room temperature Rotate the thermostat selector counter clockwise for lower cool settings Lower cool settings will provide higher...

Page 23: ...ROL OPERATING INSTRUCTIONS Auto Low Med High Follow Me Auto Cool Dry Fan Mode Fan Energy Saver Check Filter On Off Sleep Timer Ion TEMP TIMER Low Auto Med High TEMP TIMER Auto Cool Dry Fan Fan Mode On...

Page 24: ...the remote control towards the unit and press the Follow Me button T If the unit does not receive the Follow Me signal during any 7 minutes interval the unit will beep to indicate the Follow Me mode...

Page 25: ...e sure to unplug the unit before cleaning to prevent shock or fire hazards Air Filter Cleaning 23 The air filter should be checked at least once a month to see if cleaning is necessary Trapped particl...

Page 26: ...cted Push plug firmly into wall outlet House fuse blown or circuit breaker tripped Replace fuse with time delay type or reset circuit breaker Plug Current Device Tripped Press the RESET button Problem...

Page 27: ...stricted Clean air filter Air movement sound This is normal If too loud set to a slower FAN setting Outside temperature extremely hot Set FAN speed to a Higher setting to bring air past cooling coils...

Page 28: ...n and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the serv...