Specifications
Page 22
7. Capacity Correction Factor for Height Difference
Capacity(Btu/h)
12k
Pipe Length (m)
Cooling
5
10
15
20
Height difference
H (m)
Indoor Upper
than Outdoor
8
0.951
0.917
0.896
5
0.995
0.961
0.927
0.905
0
1.000
0.966
0.931
0.910
Outdoor Upper
than Indoor
-5
1.000
0.966
0.931
0.910
-8
0.966
0.931
0.910
Capacity(Btu/h)
18k
Pipe Length (m)
Cooling
5
10
15
25
Height difference
H (m)
Indoor Upper
than Outdoor
10
0.960
0.934
0.884
5
0.995
0.969
0.944
0.893
0
1.000
0.974
0.949
0.897
Outdoor Upper
than Indoor
-5
1.000
0.974
0.949
0.897
-10
0.974
0.949
0.897
Capacity(Btu/h)
24k
Pipe Length (m)
Cooling
5
10
15
25
Height difference
H (m)
Indoor Upper
than Outdoor
10
0.960
0.934
0.884
5
0.995
0.969
0.944
0.893
0
1.000
0.974
0.949
0.897
Outdoor Upper
than Indoor
-5
1.000
0.974
0.949
0.897
-10
0.974
0.949
0.897
Summary of Contents for Forest MOAA31-12CN1-NB8
Page 1: ...FOREST R410A ONOFF CONTROL TM_AF_R410A_ONOFF_SA_NA_2008 TECHNICAL MANUAL ...
Page 8: ...Specifications Page 8 3 2 Outdoor Unit 12k ...
Page 9: ...Specifications Page 9 18k ...
Page 10: ...Specifications Page 10 24k ...
Page 12: ...Specifications Page 12 24k ...
Page 14: ...Specifications Page 14 18k 24k ...