Service Manual_2020-V1.0
67
9.6 Error code and solutions
Note: Midea full common fault code, combined with the actual product display reference.
Error code
Fault Type
Troubleshooting and Solutions
E0
Initialization fault
of freeze ice
maker
Step 1
: Check whether the connection terminals on the ice maker and
the main PCB are plugged in place and whether there are foreign
matters in them; after cleaning the terminals, plug them in again.
Step 2
: Enter the forced ice making mode and check whether the ice
maker works normally.
Step 3
: If the ice maker does not work, replace the ice motor.
Step 4
: If the fault still occurs, replace the main PCB.
E1
Temperature
sensor fault in
refrigerating
chamber
Step 1
: Check whether the connection terminals are plugged in place
and whether there are foreign matters in them; after cleaning the
terminals, plug them in again.
Step 2
: If the fault still occurs, pull out the corresponding connection
terminal on the main PCB, use a multimeter to check the resistance
value of the sensor, and confirm whether it is normal.
Step 3
: If the resistance value is wrong, replace the sensor.
Step 4
: If the fault still occurs, replace the main PCB.
E2
Temperature
sensor fault in
freezing chamber
E3
Temperature
sensor fault in
variable chamber
C9
Sensor fault of
ice-making
compartment
E4
Defrost sensor
fault in
refrigerating
chamber
Step 1
: Check whether the connection terminals are plugged in place
and whether there are foreign matters in them; after cleaning the
terminals, plug them in again.
Step 2
: If the fault still occurs, pull out the corresponding connection
terminal on the main PCB, use a multimeter to check the resistance
value of the sensor, and confirm whether it is normal.
Step 3
: If the resistance value is wrong, replace the sensor.
Step 4
: If the fault still occurs, replace the main PCB.
E5
Defrost sensor
fault in freezing
chamber
CC
Defrosting fault of
ice-making
compartment
E6
Communication
failure
Step 1
: Check whether the connection terminal on the display control
panel, hinge cover and main PCB are plugged in place and whether
there are foreign matters in them; after cleaning the terminals, plug
them in again.
Step 2
: If the fault still occurs, pull out all connection terminals, use a
multimeter to check the resistance value of the wire between the
display control board and the main PCB to see if it is broken. If test
value is ∞Ω, the wire is broken.(If the wire in the door is broken,
replace the door. Other conditions cannot be repaired.)
Step 3
: If the wire is OK, replace the display control board.
Step 4
: If the fault still occurs, replace the main PCB.
E7
Ambient
temperature
Step 1
: Check whether the connection terminals are plugged in place
Summary of Contents for French-Door Series
Page 5: ...Service Manual_2020 V1 0 5 1 Significant update notes None ...
Page 22: ...Service Manual_2020 V1 0 22 5 5 Inverter board terminal connection diagram Option ...
Page 74: ...Service Manual_2020 V1 0 74 11 Troubleshooting Method 11 1 No cooling Air cooling Electronic ...
Page 75: ...Service Manual_2020 V1 0 75 ...
Page 76: ...Service Manual_2020 V1 0 76 11 2 No working of compressor ...
Page 77: ...Service Manual_2020 V1 0 77 11 3 Inside frosting no defrosting ...
Page 78: ...Service Manual_2020 V1 0 78 11 4 Inside frosting no defrosting Maintenance guidelines ...
Page 79: ...Service Manual_2020 V1 0 79 11 5 Light is not on ...
Page 80: ...Service Manual_2020 V1 0 80 11 6 Fan failure 11 7 Defective defrost circuit ...
Page 81: ...Service Manual_2020 V1 0 81 11 8 Noise 11 9 Air duct not operated ...
Page 82: ...Service Manual_2020 V1 0 82 11 10 Ice makernot make ice Option ...
Page 83: ...Service Manual_2020 V1 0 83 11 11 No ice or crushed ice falling off the distributor Option ...