Service Manual_2018-V2.0
35
1)Unplug the wiring connector by pressing the terminal
lock
2) Loosen the screw, then pull out the fan bracket
towards the direction what the arrows indicate.
Back hanging wire tube condensor
None
Piping system in the compressor case
❶
Suction Pipe
❷
Capillary Tube
❸
Anti-water condensed pipe
❹
Drier
❺
Compressor
❻
Condenser fan
❼
Condenser
❽
Anti-water condensed pipe
Drain tray
1
)
Remove the bottom screws of the compressor bottom
plate
Summary of Contents for HC-957WEN
Page 5: ...Service Manual_2018 V2 0 5 1 Significant update notes None...
Page 24: ...Service Manual_2018 V2 0 24 7 3Circulating route of cooling air...
Page 52: ...Service Manual_2018 V2 0 52 12 Troubleshooting Method 12 1 No cooling Air cooling Electronic...
Page 53: ...Service Manual_2018 V2 0 53 12 2 No working of compressor 12 3 Inside frosting no defrosting...
Page 54: ...Service Manual_2018 V2 0 54 12 4 Inside frosting no defrosting Maintenance guidelines...
Page 55: ...Service Manual_2018 V2 0 55 12 5 Light is not on 12 6Fan failure...
Page 56: ...Service Manual_2018 V2 0 56 12 7Defective defrost circuit 12 8Noise...
Page 58: ...Service Manual_2018 V2 0 58 13 Figures and details of repair parts See this section in the TSP...