installation manual
8 WIRING
The appliance shall be installed in accordance with
national wiring regulations.
The air conditioner should use separate power supply
with rated voltage.
The external power supply to the air conditioner should
be grounded, which is linked to the ground wiring of the
indoor and outdoor unit.
The wiring work should be done by qualified persons
according to wiring diagram.
A circuit breaker and a residual current device (RCD) with
above 10mA rating shall be installed in the power circuit
according to the national rule.
Be sure to locate the power wiring and the signal wring
well to avoid cross-disturbance.
Do not turn on the power until you have confirmed
proper wiring.
The power cord type is H07RN-F.
The power connection for the air conditioner has to be
done at the main power distribution. The distribution has
to be of a low impedance, normally the required
impedance reaches at a 32A fusing point.
No other equipment has to be connected with this power
line.
For detailed installation acceptance please refer to your
power supplier, if restrictions do apply for products like
washing machines, air conditioners or electrical ovens.
For power details of the air conditioner refer to the rating
nameplate of the product.
For any question contact your local dealer.
1
2
4
3
5
Refer to EMC Directive 2004/108/EC
To prevent flicker impressions during the start of the
compressor
,
following installation conditions do apply.
NOTE
Disassemble the cover.(If there isn't a cover on the outdoor
unit, disassemble the screw from the maintenance board, and
pull it in the direction of the arrow to remove the protection
board.)
(Refer to Fig 8.1)
Connect the cables to the terminals correspondingly.
Re-install the cover or the protection board.
Connect the cable
8.1
Fig 8.1
Protection board
All the figures in this manual are for explanation purpose only.
They may be slightly different from the air conditioner you
purchased(depend on model).The actual unit shall prevail.
NOTE
Wiring figure
8.2
Cover
For ensuring throttled efficiency , Please mount the Orifice as
horizontally as possible; and anti-shock rubber should be
wrapped at external of the Orifice for denoise.
NOTE
7 CONNECTIVE DIAGRAM
Fig 7.1
Liquid side
Gas side
Please use heat-resistant materials as heat insulation materials
of the air-side pipe. (e.g., EPT)
Cover heat insulation materials separately at the liquid side and
the air side. Moreover, perform heat insulation thoroughly for the
air-side pipes of the indoor unit, and prevent water from dripping
outside the unit.
After applying the auxiliary heat insulation materials, use
vinylresin tape to seal it lest water leak.
Fig.6-1
6.2 Heat Insulation Of The Refrigerant Pipe
Indoor unit
(air-side pipe)