32
10.1 Indoor Unit Error Display
Operation lamp
Timer lamp
Display
LED STATUS
☆
1 time
X
E0
Indoor unit EEPROM parameter error
☆
2 times
X
E1
Indoor / outdoor units communication error
☆
3 times
X
E2
Zero-crossing signal detection error
☆
4 times
X
E3
Indoor fan speed has been out of control
☆
5 times
X
E4
Indoor room temperature sensor T1 open circuit or short
circuit
☆
6 times
X
E5
Evaporator coil temperature sensor T2 open circuit or
short circuit
☆
7 times
X
EC
Refrigerant leakage detection
☆
2 times
O
F1
Outdoor temperature sensor T4 open circuit or short
circuit
☆
3 times
O
F2
Condenser coil temperature sensor T3 open circuit or
short circuit
☆
4 times
O
F3
Compressor discharge temperature sensor T5 open
circuit or short circuit
☆
5 times
O
F4
Outdoor unit EEPROM parameter error
☆
1 times
☆
P0
IPM malfunction or IGBT over-strong current protection
☆
2 times
☆
P1
Over voltage or over low voltage protection
☆
3 times
☆
P2
High temperature protection of compressor top diagnosis
and solution
☆
5 times
☆
P4
Inverter compressor drive error
Summary of Contents for MCHS-09NIH1
Page 11: ...9 6 Wiring Diagram 6 1 Indoor Unit MEHS 09NiH1 MEHS 12NiH1 MEHS 09NiH2 MEHS 12NiH2 MEHS 18NiH2...
Page 12: ...10 MEHS 22NiH2...
Page 13: ...11 6 2 Outdoor Unit MCHS 09NiH1 MCHS 12NiH1...
Page 14: ...12 MCHS 09NiH2 MCHS 12NiH2...
Page 15: ...13 MCHS 18NiH2 MCHS 22NiH2...
Page 16: ...14 For MCHS 12NiH2 For MCHS 09NiH1 MCHS 12NiH1...
Page 17: ...15 For MCHS 09NiH2 For MCHS 18NiH2...
Page 18: ...16 For MCHS 22NiH2...
Page 50: ...48 P W P N...