R410A tropical air-cooled scroll chiller unit 60Hz MCAC-ATSM-2014-09
122
15.2 Wired controller KJRM-120D/BMK-E(Standard)
15.2.1. Operating instructions of buttons
○
1 .
Operation icon
: Indicate the ON and OFF status; when it is ON, it will display; when it is OFF, it
will disappear;
○
2 .
Mode area
: Indicate the main unit operating mode;
○
3 .
Setting temperature
: 2 status can be displayed:
;
○
4 .
Timing ON/OFF indication
: Indicate the timing information;
○
5
.Function icon
:
1) Computer: Display when connects to computer;
2) Maintenance: When the icon is lighted on it means should arrange professionals to do the cleaning
maintenance; long press “CONSTRAINT” for 3 seconds then this icon will be off, until the next maintenance;
3) E-heating: Display when the electric auxiliary heating water function is operated;
4) Check: Display when check function is operated;
5) Anti-freezing: Display when the main unit ambient temperature is below 2
℃
, to remind the main unit
should be do the anti-freezing measurement;
6) Lock: When the icon is lighted on, it means the button has been locked (no keys operation for 2 minutes),
long press “OK” key for 3 seconds to unlock;
7) Error: When the main unit has error or protection, this icon will be displayed. The unit needs to be
maintained by professionals.
○
6
. On-line unit quantity indication:
Under normal status display the quantity of the units connected to
the wired controller; under check status display the device serial number;
○
7
. Reserved
;
14
13
3
1
2
4
16
11
15
5
6
7
8
9
10
11
12
1. Operation icon
2. Mode area
3. Setting temperature
4. Timing On/Off
5. Function icon
6. On-line unit qt y.
7. Reserved
8. Clock
9. Water temp.
10.ON/OFF key
11.Right, Left key
12.OK key
13. Setting key
14. Add, reduce key
15. Cancel key
16. Reserved
key
Summary of Contents for MGBT-F120W/PN1
Page 28: ...MCAC ATSM 2014 09 R410A tropical air cooled scroll chiller unit 60Hz 29 60kW module ...
Page 29: ...R410A tropical air cooled scroll chiller unit 60Hz MCAC ATSM 2014 09 30 120kW module ...
Page 30: ...MCAC ATSM 2014 09 R410A tropical air cooled scroll chiller unit 60Hz 31 180kW module ...
Page 32: ...MCAC ATSM 2014 09 R410A tropical air cooled scroll chiller unit 60Hz 33 60kW module ...
Page 33: ...R410A tropical air cooled scroll chiller unit 60Hz MCAC ATSM 2014 09 34 120kW module ...
Page 34: ...MCAC ATSM 2014 09 R410A tropical air cooled scroll chiller unit 60Hz 35 180kW module ...
Page 36: ......
Page 46: ...MCAC ATSM 2014 09 R410A tropical air cooled scroll chiller unit 60Hz 47 ...
Page 48: ...MCAC ATSM 2014 09 R410A tropical air cooled scroll chiller unit 60Hz 49 MGCT D30W PN1 ...
Page 49: ...R410A tropical air cooled scroll chiller unit 60Hz MCAC ATSM 2014 09 50 ...
Page 51: ...R410A tropical air cooled scroll chiller unit 60Hz MCAC ATSM 2014 09 52 10 2 MGBT F60W PN1 ...
Page 54: ...MCAC ATSM 2014 09 R410A tropical air cooled scroll chiller unit 60Hz 55 ...
Page 55: ...R410A tropical air cooled scroll chiller unit 60Hz MCAC ATSM 2014 09 56 ...
Page 57: ...R410A tropical air cooled scroll chiller unit 60Hz MCAC ATSM 2014 09 58 10 4 MGBT F180W PN1 ...
Page 82: ...MCAC ATSM 2014 09 R410A tropical air cooled scroll chiller unit 60Hz 83 ...