Maintenance and
Disassembly
Page 65
MOB01-09HFN1-MW0W, MOB01-12HFN1-MV0W, MOCA01-18HFN1-MT0W
Procedure
Illustration
1) Remove the connector for the
compressor (see
CJ_ODU_INV_016).
2) Pull out the two blue wires connected
with the four way valve (see
CJ_ODU_
INV_016).
3) Pull out connectors of the condenser
coil temp. sensor(T3),outdoor ambient
temp. sensor(T4) and discharge temp.
sensor(TP) (see
CJ_ODU_INV_016).
4) Disconnect the electronic expansion
valve wire (see Fig
CJ_ODU_INV_016).
5) Remove the connector for the reactor
(see Fig
CJ_ODU_INV_016).
6) Then remove the electronic control
box.
CJ_ODU_INV_016
Note: This section is for reference only. Actual unit appearance may vary.
Compressor
T3, T4, TP
Electronic Expansion Valve
Reactor
DR
4-Way Valve