45
l
The forced operation function can not be memorized if power off.
8.4.7 Timer function
8.4.7.1 Timing range is 24 hours.
8.4.7.2 Timer on. The machine will turn on automatically when reaching the setting time.
8.4.7.3 Timer off. The machine will turn off automatically when reaching the setting time.
8.4.7.4 Timer on/off. The machine will turn on automatically when reaching the setting
“
on
”
time, and
then turn off automatically when reaching the setting
“
off
”
time.
8.4.7.5 Timer off/on. The machine will turn off automatically when reaching the setting
“
off
”
time, and
then turn on automatically when reaching the setting
“
on
”
time.
8.4.7.6 The timer function will not change the AC current operation mode. Suppose users set the
“
timer off
”
function and AC is off now, the AC will keep the current running mode and then turn off when
reaching the setting time.
8.4.7.7 The setting time is relative time.
8.4.8 Sleep function mode
8.4.8.1 Operation time in sleep mode is 7 hours. After 7 hours, the AC quits this mode and turns off.
8.4.8.2. Operation process in sleep mode is as follow:
After pressing ECONOMIC or SLEEP button on controller, the machine will turn into sleep mode.
When cooling, the setting temperature rises 1
(be lower than 30
) every one hour,
℃
℃
2 hours later the
setting temperature stops rising and indoor fan is fixed as low speed.
When heating, the setting temperature decreases 1
(be higher than 17
) every one hour, 2 hours
℃
℃
later the setting temperature stops rising and indoor fan is fixed as low speed.(Anti-cold wind function
has the priority)
8.4.8.3 Timer setting is available.
8.4.8.4 When user uses timer off function in sleep mode(or sleep function in timer off mode), if the
timing is less than 7 hours, sleep function will be cancelled when reaching the setting time. If the timing
is more than 7 hours, the machine will not stop until reaches the setting time in sleep mode.
8.4.9 Auto-Restart function
The indoor unit is equipped with auto-restart function, which is carried out through an auto-restart
module. In case of a sudden power failure, the module memorizes the setting conditions before the
power failure. The unit will resume the previous operation setting (not including Swing function)
Summary of Contents for MOA-07HN1-QC2
Page 11: ...9 3 Dimension 3 1 Indoor Units Figure 1 Figure 2...
Page 16: ...14 MSX 21HRN1 QB8W MSX 24HRN1 QB8W...
Page 17: ...15 5 2 Outdoor Units MOA 07HN1 QC2...
Page 18: ...16 MOA1 09HN1 QC2 MOA 09HN1 QC2 MOB1 12HN1 QC2 MOB 12HN1 QC2...
Page 19: ...17 MOF 18HN1 QC2...