48
9.2 Diagnosis and Solution
9.2.1 Indoor fan speed out of control diagnosis and solution
Is the fan motor connector and
connection good?
The unit does not work
normally
Turn off the unit, rotate the cross
fan. Does it rotate freely?
No
Disassemble the connection between
the fan and the motor, check if the
bearing is normal. If not, change the
bearing. If yes, follow the below step.
Yes
The problem is not
resolved.
Yes
Shut off the power supply and turn
on it 5s later
Replace the outdoor fan motor
Replace the outdoor PCB