44
Running rules:
No
Condition
Indoor fan
Compressor
1
T1- Ts
≧
2
Low
Breeze
ON 6 minutes
OFF 4 minutes
2
0
≤T
1- Ts
<
2
Low
Breeze
ON 5 minutes
OFF 5 minutes
3
T1- Ts
<
0
Low
Breeze
ON 4 minutes
OFF 6 minutes
In drying mode, if the room temperature is lower than 10
℃
, the indoor fan will run at breeze
while the compressor and outdoor fan will stop and not resume until room temperature exceeds 13
℃
.
For 21k,24k models:
8.4.5.2 The indoor fan keeps run at low speed. The compressor and outdoor fan run the same as in
cooling mode.
8.4.5.3 The system protection is active in this mode.
8.4.6 Forced operation function
Press the touch button continually, the AC will run as below sequence:
Forced auto
→Forced cooling
→Off
Forced cooling mode:
The compressor and outdoor fan keep running and the indoor fan runs at low speed. After running for
30 minutes, AC will turn to drying mode with 24
℃
setting temperature.
Forced auto mode:
The action of forced auto mode is the same as normal auto mode with 24
℃
setting temperature.
When AC receives signals, such as switch on, switch off, timer on, timer off, mode setting, fan
speed setting, sleep mode setting, follow me setting, it will quit the forced operation.
8.4.7 Timer function
8.4.7.1 Timing range is 24 hours.
8.4.7.2 Timer on. The machine will turn on automatically when reaching the setting time.
8.4.7.3 Timer off. The machine will turn off automatically when reaching the setting time.
8.4.7.4 Timer on/off. The machine will turn on automatically when reaching the setting “on” time, and
Summary of Contents for MOA-11HN1-QB8
Page 1: ...LUNA ON OFF SERIES Service Manual 2014 9ASEU B1 1401...
Page 16: ...14 MS9A 12HRN1 QC7G...
Page 17: ...15 MS9A 18HRN1 QC5...
Page 18: ...16 MS9A 24HRN1 QB8W...
Page 20: ...18 MOC 17HN1 QC0...
Page 21: ...19 MOC 18HN1 QC0 MOF3 18HN1 QC5...
Page 22: ...20 MOP 24HN1 QB8W...
Page 23: ...21 MOF1 24HN1 QB8W...