background image

CONTENTS

1. PREFACE

    1.1 SAFETY PRECAUTIONS..................................................................................1
    1.2 INSULATION RESISTANCE TEST......................................................................1
    1.3 SPECIFICATIONS............................................................................................2
    1.4 FEATURES......................................................................................................4
    1.5 DISPLAY PANEL AND REMOTE CONTROL........................................................4

2. INSTALLATION

    2.1 NAMES OF PARTS...........................................................................................5
    2.2 WINDOW INSTALLATION.................................................................................6

3. TROUBLESHOOTING GUIDE

    3.1 PIPING SYSTEM..............................................................................................7
    3.2 ELECTRIC FUNCTION......................................................................................7
    3.3 TROUBLESHOOTING GUIDE............................................................................8

4. SCHEMATIC DIAGRAM

    4.1 CIRCUIT DIAGRAM.........................................................................................13

5. EXPLODED VIEW AND REPLACEMENT
    PARTS LIST

..................................................   ....................................................14

1.PREFACE

This SERVICE MANUAL provides various service information, including the mechanical and electrical
parts etc. This room air conditioner was manufactured and assembled under a strict quality control system.
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.

1.1 SAFETY PRECAUTIONS

1. When servicing the unit, set the  POWER SWITCH to OFF and unplug the power cord.
2. Observe the original lead dress.
    If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit.
3. After servicing the unit, make an insulation resistance test to protect the customer from being exposed to 
    shock hazards.

1.2 INSULATION RESISTANCE TEST

1. Unplug the power cord and connect a jumper between 2 pins (black and white).
2. The grounding conductor (yellow/green) is to be open.
3. Measure the resistance value with an ohm metre between the jumped lead and each exposed metallic part
    on the equipment at all the positions.
4. The value should be over 1M

.

1

Summary of Contents for MPA-08CE

Page 1: ...Service Manual Mobile type GD Midea Refrigeration Equipment Co Ltd Model applied MPA 08CE MPA 08CR MPA 08EE MPA 08ER...

Page 2: ...m The refrigerant is charged at the factory Be sure to read the safety precautions prior to servicing the unit 1 1 SAFETY PRECAUTIONS 1 When servicing the unit set the POWER SWITCH to OFF and unplug t...

Page 3: ...luminium Hydrophilic aluminium e Tube outside dia and type mm 7 94x0 35 innergroove tube 7 94x0 35 innergroove tube f Coil length x height x width mm 274x264x38 1 274x264x38 1 g Number of circuits 1 1...

Page 4: ...Fin type code Hydrophilic aluminium Hydrophilic aluminium e Tube outside dia and type mm 7 94x0 35 innergroove tube 7 94x0 35 innergroove tube f Coil length x height x width mm 274x264x38 1 274x264x38...

Page 5: ...I 6 Remote display 7 Mode button 8 9 Fan button A B C Swing button D Up button E Clock button F Reset button G Lock button H I Timer on button Timer off button Display the situation of operation setti...

Page 6: ...COVER DRAIN TANK 2 INSTALLATION Installation Accessories Description Quantity Flexible exhaust hose with adapters 3 set 1 3 stretches from 19 50cm up to 78 200cm 2 4 Window exhaust adapter flat mouth...

Page 7: ...nside the cabinet otherwise the unit will not operate 5 To turn the unit on press the I O key On Off Switch Water Tank Safety Feature This unit is equipped with a fail safe switch mechanism which prev...

Page 8: ...2 1 THE SETTING OF AUTO SWING When the air conditioner is operating press the SWING key at any mode to start the auto swing 3 2 2 OFF TIMER Set the OFF TIMER at any mode when the air condition is oper...

Page 9: ...minutes re starting the machine after the compressor is stopped needs to wait for 3 minutes 3 2 5 5 CURRENT PROTECTION FOR COMPRESSOR During operation if over current lasts for 3 seconds the compresso...

Page 10: ...Check fan motor capacitor Is the voltage of CN11 on main board correct Replace main board Yes No Replace fan motor Yes Check Whether the evaporator or condenser is blocked Check compressor capacitor C...

Page 11: ...eck fan speed Yes No Replace main board Check air filter Is temperature of suction pipe on compressor higher o than 19 C No Replace compressor Check leakage repair and recharge refrigerant Yes Check r...

Page 12: ...f knocking sounds continue when running or loose or the motor hums or noise appears to be internal while running Copper tubing Remove the cabinet and carefully rearrange tubing not to contact cabinet...

Page 13: ...maged Water depth controller switch Check whether the water tank is in correct postiong Replace the water depth controller switch if checked failure Main board Check and replace the main board after c...

Page 14: ...13 4 SCHEMATIC DIAGRAM 4 1 CIRCUIT DIAGRAM For Model MPA 08CE and MPA 08CR For Model MPA 08EE and MPA 08ER...