background image

5

5

6

6

OPERATING INSTRUCTIONS

8.   Connecting  pipe 
9.   Connecting  cable
10. Stop valve

Outdoor unit

Outdoor unit

1.   Front panel
2.   Air inlet
3.   Air filter
4.   Air outlet
5.   Horizontal air flow grille
6.   Vertical air flow louver(inside)
7.   Display panel 

Indoor unit

Indoor unit

Special functions

Turbo function enables the unit to reach the preset temperature in the shortest time. When press 
this button on cooling mode, the unit will blow strong cooling air with super high fan speed. 
When press this button on heating mode (applicable to the unit adopts Electric heater only), the 
Electric heater will be energized and bring fast heating operation.  

 

TURBO function(on  some  models)

SELF CLEAN  function

Optional

Refrigerant Leakage Detection 

Vertical swing  function

Optional

 After the AC starts up, users can control the vertical louver swing by the remote controller.

 

4

3

5

2

6

1

9

10

8

7

RUN indication lamp

This lamp  illuminates when the air 
conditioner is in operation.

TURBO indication lamp

(optional function)

This lamp  illuminates when TURBO feature 
is activated.

TIMER indication lamp

Lights up during Timer operation.

DEFROST indication lamp

(Applicable to cooling & heating models only): 
Lights up  when the air conditioner  starts  
defrosting automatically or  when the warm 
air control feature is activated in heating 
operation. 

Temperature indicator

Displays the temperature settings when the 
air conditioner is operational.
Displays the malfunction code.

With this new technology, the dipsplay area will appear  EC   or the LED indication lamps
keep flashing (depending on models) when the outdoor unit detects refrigerant leakage. 

,

,

Function used after the Shut Down of cooling operation to clean the Evaporator and keep it 
as fresh for the next operation. 
The unit  will operate as following sequence : FAN ONLY mode at Low fan speed--Heating 
operation with LOW fan speed(applicable to cooling & heating modles only) ---FAN ONLY 
operation--Stop Operation---Turn off. 

Note:

 

This function is only available under COOL(AUTO COOL, FORCED COOL) and DRY mode. 
Before select the function, it is recommended to run the air conditioner under Cooling 
operation for about half an hour. 
Once the Self Clean function is activated, all TIMER setting will be cancelled.
During Self Clean  operation, when press the SELF CLEAN  button on the remote controller 
again will stop the operation and turn off the unit automatically.

 

turbo defrost  run   timer

NAMES OF PARTS

Indication lamp

Indication lamp

NOTE:

          All the pictures in this manual are for 
          explanation purposes only. The actual shape 
          of the indoor unit you purchased may be slight 
          different on front panel and display window.The 
          actual shape shall prevail.

Names of parts

Louver Angle Memory Function(optional): 

Within the scope of safety angle, it will memorize the open angle of horizontal louver. 
If it exceeds, it will memorize the boundry of safety angle. In the following circumstances, 
it will return to standard angle: 1) pressing the manual switch, 2)unplug and then plug
in the machine. So we strongly suggest that the open angle of the horizontal louver should 
not be set too small, in case the condensed water forms and drops from the horizontal louver.

Anti-mildew function

Optional

When turns off the unit  on COOL, DRY, AUTO (Cool) mode, the air conditioner will continue 
operating for about 7-10 minutes (depending on models) at LOW fan speed. If turns off on 
HEAT mode, the unit will continue operating for about 30 seconds at LOW fan speed. 

This will 

help to dry up the condensed water inside the evaporator, and prevent the breeding of mildew. 
Under Anti-mildew operation, do not restart the air conditioner until the unit is completely off.

 

Summary of Contents for ms11m series

Page 1: ...ications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details 2020001B8020 Before using your air conditioner please read this ma...

Page 2: ...in the European countries please read the following information This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or l...

Page 3: ...ll the air conditioner in places where combustible gas can be emitted Emmitted gas may collect and cause an explosion Never allow the air conditioner to run for too long with the doors or windows open...

Page 4: ...the next operation The unit will operate as following sequence FAN ONLYmode at Low fan speed Heating operation with LOW fan speed applicable to cooling heating modles only FAN ONLY operation Stop Ope...

Page 5: ...tion Operating temperature Manual switch Manual switch Mode Temperature Room temperature Outdoor temperature 1 Optimum performance will be achieved within these operating temperatures If air condition...

Page 6: ...y stop running Clean the air filter periodically otherwise cooling or heating performance may be reduced Do not operate unit with horizontal louvre in closed position The fan speed will be automatical...

Page 7: ...mpressor can t restart for 3 4 minutes after it stops Anti cold air Cooling and heating models only The unit is designed not to blow cold air on HEAT mode when the indoor heat exchanger is in one of t...

Page 8: ...abnormally Trouble OPERATION indicator or other indicators continue flashing If one of the following code appears on the display area E0 E1 E2 E3 or P0 P1 P2 P3 TROUBLESHOOTING TIPS Troubleshooting gu...

Reviews: