5
5
6
6
OPERATING INSTRUCTIONS
8. Connecting pipe
9. Connecting cable
10. Stop valve
Outdoor unit
Outdoor unit
1. Front panel
2. Air inlet
3. Air filter
4. Air outlet
5. Horizontal air flow grille
6. Vertical air flow louver(inside)
7. Display panel
Indoor unit
Indoor unit
Special functions
Turbo function enables the unit to reach the preset temperature in the shortest time. When press
this button on cooling mode, the unit will blow strong cooling air with super high fan speed.
When press this button on heating mode (applicable to the unit adopts Electric heater only), the
Electric heater will be energized and bring fast heating operation.
TURBO function(on some models)
SELF CLEAN function
Optional
Refrigerant Leakage Detection
Vertical swing function
Optional
After the AC starts up, users can control the vertical louver swing by the remote controller.
4
3
5
2
6
1
9
10
8
7
RUN indication lamp
This lamp illuminates when the air
conditioner is in operation.
TURBO indication lamp
(optional function)
This lamp illuminates when TURBO feature
is activated.
TIMER indication lamp
Lights up during Timer operation.
DEFROST indication lamp
(Applicable to cooling & heating models only):
Lights up when the air conditioner starts
defrosting automatically or when the warm
air control feature is activated in heating
operation.
Temperature indicator
Displays the temperature settings when the
air conditioner is operational.
Displays the malfunction code.
With this new technology, the dipsplay area will appear EC or the LED indication lamps
keep flashing (depending on models) when the outdoor unit detects refrigerant leakage.
,
,
Function used after the Shut Down of cooling operation to clean the Evaporator and keep it
as fresh for the next operation.
The unit will operate as following sequence : FAN ONLY mode at Low fan speed--Heating
operation with LOW fan speed(applicable to cooling & heating modles only) ---FAN ONLY
operation--Stop Operation---Turn off.
Note:
This function is only available under COOL(AUTO COOL, FORCED COOL) and DRY mode.
Before select the function, it is recommended to run the air conditioner under Cooling
operation for about half an hour.
Once the Self Clean function is activated, all TIMER setting will be cancelled.
During Self Clean operation, when press the SELF CLEAN button on the remote controller
again will stop the operation and turn off the unit automatically.
turbo defrost run timer
NAMES OF PARTS
Indication lamp
Indication lamp
NOTE:
All the pictures in this manual are for
explanation purposes only. The actual shape
of the indoor unit you purchased may be slight
different on front panel and display window.The
actual shape shall prevail.
Names of parts
Louver Angle Memory Function(optional):
Within the scope of safety angle, it will memorize the open angle of horizontal louver.
If it exceeds, it will memorize the boundry of safety angle. In the following circumstances,
it will return to standard angle: 1) pressing the manual switch, 2)unplug and then plug
in the machine. So we strongly suggest that the open angle of the horizontal louver should
not be set too small, in case the condensed water forms and drops from the horizontal louver.
Anti-mildew function
Optional
When turns off the unit on COOL, DRY, AUTO (Cool) mode, the air conditioner will continue
operating for about 7-10 minutes (depending on models) at LOW fan speed. If turns off on
HEAT mode, the unit will continue operating for about 30 seconds at LOW fan speed.
This will
help to dry up the condensed water inside the evaporator, and prevent the breeding of mildew.
Under Anti-mildew operation, do not restart the air conditioner until the unit is completely off.