Service manual
22
9.5 MSF3-12CRN2
Cooling mode
Outdoor temperature (Dry bulb temp)
Indoor
Conditions
Pressure
25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
21ºC D
15ºC W
Pressure
( kg/cm
2
)
8.4 8.5 8.8 8.9 9.4 9.9
24ºC D
17ºC W
Pressure
( kg/cm
2
)
8.6 8.8 9.2 9.4 10.0 10.4
27ºC D
19ºC W
Pressure
( kg/cm
2
)
8.8 9.2 9.4 9.8 10.3 10.9
32ºC D
23ºC W
Pressure
( kg/cm
2
)
9.2 9.6 9.9 10.4 10.8 11.2
9.6 MSF3-12HRN2
Cooling mode
Outdoor temperature (Dry bulb temp)
Indoor
Conditions
Pressure
25ºC 30ºC 35ºC 40ºC 45ºC 50ºC
21ºC D
15ºC W
Pressure
( kg/cm
2
)
8.4 8.5 8.8 8.9 9.4 9.9
24ºC D
17ºC W
Pressure
( kg/cm
2
)
8.6 8.8 9.2 9.4 10.0 10.4
27ºC D
19ºC W
Pressure
( kg/cm
2
)
8.8 9.2 9.4 9.8 10.3 10.9
32ºC D
23ºC W
Pressure
( kg/cm
2
)
9.2 9.6 9.9 10.4 10.8 11.2
Heating mode
OUTDOOR CONDITIONS
Indoor
Conditions
Pressure
12ºC D
11ºC W
7ºC D
6ºC W
0ºC D
-1ºC W
-4ºC D
-6ºC W
-7ºC D
-9ºC W
-15ºC D
-xºC W
15ºC
Pressure
( kg/cm
2
)
27.4 25.9 22.2 21.4 20.0 /
18ºC
Pressure
( kg/cm
2
)
29.8 27.2 23.8 22.0 21.1 /
20ºC
Pressure
( kg/cm
2
)
30.2 29.1 24.2 23.6 22.1 /
22ºC
Pressure
( kg/cm
2
)
32.4 30.1 25.4 24.0 22.7 /