Service manual
11.7.3 Defrosting Actions:
max. 10 minutes
60s
ON 10s 30s
Com. OFF
ON ON
4 way valve OFF
ON ON
Outdoor fan OFF
ON ON
Indoor fan
OFF
Breeze 10 seconds, then stop
11.7.4 Rated capacity test
Set mode to cooling mode
Set temp. to 30 °C
Set fan speed to high speed
Push turbo button 5 times in 10 seconds.
Using special remoter controller
After 5 hours, cancel rated capacity test
11.8. Outdoor low temperature protection (optional)
Factory standard unit has not this function.
Unit stops when outdoor temp. is low than -15°C and lasting time more than 60 minutes, and unit runs
again when outdoor temp. more than -12°C.
When indoor PCB J1 jump is on, this function is available.
11.9. Automatic operation mode
The air conditioner automatically selects one of the following operation modes: cooling, heating or fan
only according to the temp. difference between room temp. (TA) and set temp. (TS).
TA—TS Operation
mode
TA—TS>2
℃
Cooling
-1
℃
≤
TA-TS
≤
+2
℃
Fan-only
TA-TS<-1
℃
Heating (air-only for cooling only type)
11.10. Manual switch
11.10.1
Mode changes when push this button .
Cooing mode Auto mode Unit off Cooing mode
11.10.2
At Cooing mode, after 30 minutes cooling operation whose fan speed is set as low, the A/C
operates with a setting temp. of 24
℃
.
11.10.3
At auto mode, the A/C operates with a set temp. of 24
℃
11.11. Timer Function
11.11.1
The maximum length of timer is 24 hours and the minimum resolving power is 15 minutes.
11.11.2
Timer on: first turn off the A/C, the A/C will be automatically on at the set time.
11.11.3
Timer off: first turn on the A/C, the A/C will be automatically off at the set time
11.11.4
Timer on/off function( on time is earlier than off time): first turn off the A/C, it will be
automatically on at set time, and later be off at the set time, then unit turns on at set time.
11.11.5
Timer off/on function( off time is earlier than on time): first turn on the A/C, it will be
automatically off at set time, and later be on at the set time, then unit turns off at set time.
11.12. Sleep mode
11.12.1
It is available at cooling, heating or auto mode.
11.12.2 Cooling:
The set temperature rise 1
℃
per hour. Two hours later, the set temperature will maintain as a constant
and the fan speed is kept at low speed.
28
Summary of Contents for MSV1-09HRDN1
Page 1: ...Cover MSV1 09HRDN1 MSV1 12HRDN1...
Page 4: ......
Page 11: ...Service manual 5 Refrigerant cycle diagram 7...
Page 14: ...Service manual 7 1 2 Indoor main PCB 10...
Page 15: ...Service manual 7 1 3 Outdoor main PCB 11...
Page 16: ...Service manual 7 1 4 Outdoor power PCB 12...
Page 17: ...Service manual 7 2 Wiring diagram 7 2 1 MSV1 09HRDN1 MSV1 12HRDN1 13...