Service manual
34
No
Is connection to connector good?
Yes
Yes
No
Yes
Yes
No
No
No
Yes
13.1.8
Display LED
STATUS
P1
Over voltage or too low voltage protection
13.1.9
Display LED
STATUS
P2
Compressor top protection against temperature
Off: 115
゜
C; On: 100
゜
C
Is the wires to compressor right?
Check the inverter module,
If some component
cracked or damaged?
Is it breakdown between P-N,P-U,P-V;N-W,N-U,N-V
At inverter module
Check compressor
Inverter module is defective
Repair connector
Check the voltage between P and N on inverter
module. Is it about 380V?
Test the outdoor power supply board again.
Inverter module damaged, replace it.
Is the power supply right?
Check the outdoor power board
Replace outdoor main PCB.