Specifications
Page 11
Outdoor coil
Number of rows
2.0
1.6
2.0
Tube pitch(a)x row pitch(b)
mm
25.4x22
25.4x22
25.4x22
Fin spacing
mm
1.3
1.4
1.4
Fin type (code)
Hydrophilic aluminum
Hydrophilic aluminum
Hydrophilic aluminum
Tube outside dia.and type
mm
Φ
9.52,Inner groove tube
Φ
9.52,Inner groove tube
Φ
9.52,Inner groove tube
Coil length x height x width
mm
995x762x44
990x500x1270x22
990x1270x44
Number of circuits
4
8
8
Outdoor air flow
m3/h
4000
7500
7500
Outdoor sound pressure level
dB(A)
61
66
65
Outdoor sound power level
dB(A)
66
72
74
Throttle type
EXV+Capillary
EXV+Capillary
EXV+Capillary
Outdoor unit
Dimension(W*D*H)
mm
946x410x810
952x415x1333
952x415x1333
Packing (W*D*H)
mm
1090x500x875
1095x495x1480
1095x495x1480
Net/Gross weight
Kg
81.5/87.0
106.7/119.9
111.3/124.3
Refrigerant type
Type
-
R32
R32
R32
GWP
-
675
675
675
Charged quantity
Kg
2.4
2.8
2.95
Design pressure
MPa
4.2/1.5
4.2/1.5
4.2/1.5
Refrigerant piping
Liquid side/ Gas side
mm(inch)
Φ
9.52/
Φ
15.9(3/8"/5/8")
Φ
9.52/
Φ
15.9(3/8"/5/8")
Φ
9.52/
Φ
15.9(3/8"/5/8")
Max. refrigerant pipe length
m
65
65
65
Max. difference in level
m
30
30
30
Ambient temperature
Cooling
°C
-15~50
-15~50
-15~50
Heating
°C
-15~24
-15~24
-15~24
Qty’per 20’ /40’ /40’HQ
Outdoor unit
44/96/144
22/48/48
22/48/48
Notes:
1) Capacities are based on the following conditions:
Cooling(T1): - Indoor Temperature 27°C(80.6°F) DB /19 °C(66.2°F) WB Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB
-Outdoor Temperature 35 °C(95°F) DB /24 °C(75.2°F) WB -Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB
-Interconnecting Piping Length 5m - Interconnecting Piping Length 5 m
- Level Difference of Zero. - Level Difference of Zero.
2) Capacities are Net Capacities.
3) Due to our policy of innovation some specifications may be changed without notification.