Specifications
Page 9
Outdoor coil
Number of rows
1.6
2.6
Tube pitch(a)x row pitch(b)
mm
25.4x22
25.4x22
Fin spacing
mm
1.5
1.5
Fin type (code)
Hydrophilic aluminum
Hydrophilic aluminum
Tube outside dia.and type
mm
Φ
9.52,Inner groove tube
Φ9.52,Inner groove tube
Coil length x height x width
mm
1005580x762x22
995960580x762x22
Number of circuits
4
6
Outdoor air flow
m3/h
3800
3600
Outdoor sound pressure level
dB(A)
58.5
65
Outdoor sound power level
dB(A)
67
72
Throttle type
EXV+Capillary
EXV+Capillary
Outdoor unit
Dimension(W*D*H)
mm
946x410x810
946x410x810
Packing (W*D*H)
mm
1090x500x885
1090x500x885
Net/Gross weight
Kg
56.9/61.8
73.9/78.9
Refrigerant type
Type
-
R32
R32
GWP
-
675
675
Charged quantity
Kg
2.0
2.8
Design pressure
MPa
4.3/1.7
4.3/1.7
Refrigerant piping
Liquid side/ Gas side
mm(inch)
Φ
9.52/
Φ
15.9(3/8"/5/8")
Φ9.52/Φ15.9(3/8"/5/8")
Max. refrigerant pipe length
m
50
65
Max. difference in level
m
25
30
Ambient temperature
Cooling
°C
-15~50
-15~50
Heating
°C
-15~24
-15~24
Qty’per 20’ /40’ /40’HQ
Outdoor unit
44/96/138
44/96/138
Notes:
1) Capacities are based on the following conditions:
Cooling(T1): - Indoor Temperature 27°C(80.6°F) DB /19 °C(66.2°F) WB Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB
-Outdoor Temperature 35 °C(95°F) DB /24 °C(75.2°F) WB -Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB
-Interconnecting Piping Length 5m - Interconnecting Piping Length 5 m
- Level Difference of Zero. - Level Difference of Zero.
2) Capacities are Net Capacities.
3) Due to our policy of innovation some specifications may be changed without notification.