background image

MIV V4+ Indoor Units 

 

DM12-01.01.02-08en 

 

Console Type MVD-A-VA1 

1. Feature 

1.1 Console 

type 

 

1.2  Compact unit body, space saving, nice-looking appearance   

1.2.1.  This unit body is very thin and harmonious with room. It is elegant and space saving. 

1.2.2.  The EXV is fixed inside of the indoor unit,

 

compact unit body. 

1.3 Flexible 

installation 

1.3.1.  Can be used for floor standing or lower wall applications 

1.3.2.  As a floor standing type, it can be semi or fully recessed without loss of capacity. 

1.4  High efficiency filter 

1.4.1.  Built in Formaldehyde nemesis filter 

1.4.2. Active-carbon 

and biological anti-virus filter is optional. 

1.5 High 

Comfort 

 

1.5.1.  Flexible air blow: vertical auto swing and wide angle louvers ensure that warm air reaches the 

furthest corners of the room and increase the air flow coverage 

1.5.2.  Indoor unit adopts DC motor which has five level fan speed meet different requirements.   

1.5.3.  Low noise operation, lowest to 26dB(A) 

1.5.4.  Adoption of the Fujikoki brand mechanical expansion valve which has 2000 stages element 

positioning, ensure precise flow control, as well lower modulation noise when EXV operating. 

1.6  Powerful mode can be selected for rapid cooling or heating. 

COOLING MODE                                                        HEATING MODE 

             

               

         

 

Quick cooling          to maintain temp.             anti-cold air           normal operation 

 

 

Summary of Contents for MVD22A-VA1

Page 1: ...DM12 01 01 02 08en Service manual MIV V4 Indoor units Console Type MVD22A VA1 MVD28A VA1 MVD36A VA1 MVD45A VA1...

Page 2: ...V4 Indoor Units Console Type MVD A VA1 1 Console Type 1 Feature 2 2 Specifications 4 3 Dimension 5 4 Service Space 6 5 Piping Diagrams 7 6 Wiring Diagram 8 7 Capacity Tables 9 8 Electric Characteristi...

Page 3: ...hyde nemesis filter 1 4 2 Active carbon and biological anti virus filter is optional 1 5 High Comfort 1 5 1 Flexible air blow vertical auto swing and wide angle louvers ensure that warm air reaches th...

Page 4: ...oling mode air supplying from both top and bottom Normal cooling mode from top only Normal heating mode air supplying from both top and bottom Anti cold fan mode from top only Air inlet from 4 directi...

Page 5: ...ber of circuits 1 2 2 2 Indoor air flow H M L m 3 h 430 345 229 510 430 229 510 430 229 660 512 400 Indoor noise level dB A 38 32 26 39 33 27 39 33 27 42 39 36 Indoor unit Dimension W H D mm 700 600 2...

Page 6: ...Indoor Units Console Type MVD A VA1 5 3 Dimension MVD22A VA1 MVD28A VA1 MVD36A VA1 MVD45A VA1 Main dimension Outer Length 700mm Height 600mm Depth 210mm Filter length 550mm Gas tube 12 7mm Liquid tube...

Page 7: ...ded and the influence of external air is the least The air flow can reach throughout the room The connecting pipe and drainpipe could be extracted out easily There is no direct radiation from heaters...

Page 8: ...DM12 01 01 02 08en MIV V4 Indoor Units Console Type MVD A VA1 7 5 Piping Diagrams flare nut flare nut T2B gas side motor heat exchanger fan EXV liquid side T2 T1...

Page 9: ...MIV V4 Indoor Units DM12 01 01 02 08en 8 Console Type MVD A VA1 6 Wiring Diagram...

Page 10: ...1 8 2 6 1 9 2 8 1 9 3 0 1 9 3 3 2 0 3 4 1 9 21 0 1 9 1 6 2 3 1 8 2 6 1 9 2 8 1 9 3 0 1 9 3 3 2 0 3 4 1 9 23 0 1 9 1 6 2 3 1 8 2 6 1 9 2 8 1 9 3 0 1 9 3 3 2 0 3 4 1 9 25 0 1 9 1 6 2 3 1 8 2 6 1 9 2 8 1...

Page 11: ...4 5 5 3 0 25 0 3 1 2 4 3 7 2 6 4 2 2 8 4 5 2 9 4 8 3 0 5 2 3 0 5 4 2 9 27 0 3 1 2 4 3 7 2 6 4 2 2 8 4 5 2 9 4 8 3 0 5 1 3 0 5 2 2 8 29 0 3 1 2 4 3 7 2 6 4 2 2 8 4 5 2 9 4 8 3 0 5 1 2 9 5 2 2 8 31 0 3...

Page 12: ...12 60 2 14 2 14 2 14 2 14 2 14 2 14 11 00 10 50 2 24 2 24 2 24 2 24 2 24 2 24 10 00 9 50 2 34 2 34 2 34 2 34 2 34 2 34 9 10 8 50 2 40 2 40 2 40 2 40 2 40 2 40 7 60 7 00 2 43 2 43 2 43 2 43 2 43 2 43 5...

Page 13: ...3 65 3 65 9 10 8 50 3 75 3 75 3 75 3 75 3 75 3 75 7 60 7 00 3 80 3 80 3 80 3 80 3 80 3 80 5 60 5 00 3 95 3 95 3 95 3 95 3 95 3 95 3 70 3 00 4 15 4 15 4 15 4 15 4 15 4 15 0 70 0 00 4 45 4 45 4 45 4 45...

Page 14: ...MCA MFA KW FLA MVD22A VA1 50 220 240V 198 254 0 25 15 0 012 0 0135 MVD28A VA1 50 220 240V 198 254 0 25 15 0 015 0 0158 MVD36A VA1 50 220 240V 198 254 0 25 15 0 015 0 0158 MVD45A VA1 50 220 240V 198 2...

Page 15: ...ssure level dB 0dB 0 0002 bar Audibility limits of continuous white sound Octave band center frequency Hz Sound pressure level dB 0dB 0 0002 bar Audibility limits of continuous white sound Octave band...