DM12-01.01.02-06en
MIV V4+ Indoor Units
Middle Static Pressure Duct Type MVM-A-VA1
5
Model
MVM45A-VA1 MVM56A-VA1 MVM71A-VA1
Power supply
V- Ph-Hz
220-240V~, 1Ph, 50Hz
Cooling
Capacity kW
4.5 5.6 7.1
Input W
92 92 149
Rated current
A
0.5 0.5 0.7
Heating
Capacity kW
5 6.3 8
Input W
92 92 149
Rated current
A
0.5 0.5 0.7
Indoor
fan motor
Model
YSK68-4P YSK68-4P YSK74-4P
Type
AC
MOTOR
Brand
Welling
Input W
91
91
120
Capacitor
μ
F
3.5UF/450V 3.5UF/450V 3.5UF/450V
Speed (hi/mid/lo)
r/min
1150/1020/800/700 1150/1020/800/700 1000/870/750/680
Indoor
coil
Number of rows
3 3 4
Tube pitch(a)* row
pitch(b)
mm
21X13.37 21X13.37 21X13.37
Fin spacing
mm
1.5 1.5 1.5
Fin type
Hydrophilic
aluminum
Tube outside diameter
and type
mm
Ф
7
inner groove tube
length * height * width
mm
735*40.1*254
735*40.1*254
735*53.5*254
Number of circuits
4 4 6
Indoor air flow (H/M/L)
m
3
/h
958/850/667/583 958/850/667/583 1207/1050/905/821
Indoor external static pressure (Hi)
Pa
10(10~30)
Indoor noise level (Hi/Mid/Lo)
dB(A) 41/38.9/36
41/38.9/36 43.4/40/36
Indoor
unit
Dimension (W×H×D)
mm
920×210×570 920×210×570 920×210×570
Packing (W×H×D)
mm
1135×290×655
1135×290×655
1135×350×655
Net/Gross weight
kg
27/32 27/32 30/34
Fresh Air intake hole diameter (round)
mm
Ф
92
Ф
92
Ф
92
Refrigerant type
R410A
Throttle
Type
Removable EXV (screw connection)
Model BD20FKS(L)
Design pressure
MPa
4.4/2.6
Refrigerant piping
Liquid / Gas
mm
Ф
6.35/
Ф
12.7
Ф
9.52/
Ф
15.9
Ф
9.52/
Ф
15.9
Connecting wiring
Power wiring
mm
2
3*2.5(L
≤
20m); 3*3.5(L
≤
50m)
Signal wiring
mm
2
3*0.75
Drainage water pipe diameter
Ф
32 (ID
Ф
25, OD
Ф
32)
Controller
Wireless remote controller (RM05/BG(T)E-A) - Standard
KJR-12B/DP(T)-E/ KJR-10B/DP(T)-E (6 m connection wire) - optional
Operation temp
℃
Cooling
:
17
~
32
;
Heating:10
~
28
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp. : 27°CDB, 19°CWB, outdoor
temp.:35°CDB,equivalent ref. Piping: 8m(horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB,outdoor temp.:
7°CDB,6°CWB,equivalent ref. Piping: 8m(horizontal)