Summary of Contents for MWF-12CR

Page 1: ...R CO TYPE iTiO MULTI STEP SPEED ELECTRONIC CONTROL Model MWFI 06CR I MWFI 10CR I MWFI 08CR I MWF 12CR WE_TPO_NTE Before using your air conditioner please read this manual carefully and keep it for future reference ...

Page 2: ...hart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all CAUTION Contact the authorized service technician for repair or maintenance of this unit o Contact the installer for installation of this unit The air conditioner is not intended for use by young children or infirm persons without supervision Young children should be super...

Page 3: ...y cause electric shock or fire It may cause electric shock or fire due to heat generation If the power cord is damaged it must be replaced by the manufac turer or an authorized service center or a similarly qualified per son in order to avoid a hazard It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause electric shock This could damag...

Page 4: ...njure the pet or plant It may cause electric shock and damage An oxygen shortage may occur Do not use this air conditioner to preserve precision devices food pets plants and art objects It may cause deterioration ot quality etc It may cause failure of product or ire If bracket is damaged there is concern of damage due to falling of unit Appearance may be deteriorated due to change of product color...

Page 5: ...ed wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Ensure the receptacle is accessible after the unit installation Do not run air conditioner without side protective cover in place This could result in mechanical damage within the air conditioner Do no...

Page 6: ...tallation Pinging or Switching Droplets of water hitting condenser during normal operation may cause pinging or switching sounds ELECTRONIC CONTROL OPERATING INSTRUCTIONS Before you begin thoroughly familiarize yourself with the control panel and remote as shown below and all its functions then follow the symbol for the functions you desire The unit can be controlled by the unit control alone or w...

Page 7: ... Left or Right button until the desired temperature is seen on the display This temperature will be automatically maintained anywhere between 62 F 17 C and 88 F 30 C If you want the display to read the actual room temperature see To Operate on Fan Only section TO ADJUST FAN SPEEDS Auto f _ Auto Fan High E_aeregrY On Off DO THIS _ Press to select appropriate fan speed NOTE Used to select the Fan Sp...

Page 8: ...ling for maximum cooling efficiency You can choose any fan speed you prefer e During this function the display will show the actual room temperature not the set temperature as in the cooling mode NOTE In this mode the fan will continue to run for 3 minutes after the compressor shuts off The fan then cycles on for 2 minutes at 10 minute intervals until the room temperature is above the set temperat...

Page 9: ... system will automatically revert back to display the previous temperature setting e Turning the unit ON or OFF at any time will cancel the Auto Start Stop function CHECK FILTER FEATURE Off Check Filter DO THIS Press Check Filter button NOTE This feature is a reminder to clean the Air Filter for more efficient operation The LED light will illumi nate after 250 hours of operation To reset after cle...

Page 10: ... ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure here are more features in your control that you should become familiar with The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly This prevents overheating of the compressor and possible circuit breaker tripping The fan will continue to run during this time o The c...

Page 11: ...f the unit must be outdoors not inside a building or garage NOTE Save Carton and these Installation instructions for future reference The carton is the best way to store unit during winter or when not in use Mounting Hardware 3 4 Screws Lock Frame Sash Lock 7 2 1 TOOLS NEEDED Phillips Screw Driver Drill If pilot holes are needed CAUTION When handling unit be careful to avoid cuts from sharp metal ...

Page 12: ...t using the Side Panels for any reason this pitch to the rear must be maintained H Place unit on floor a bench or a table There is a Left and Right Window Filler Panel be sure to use the proper panel for each side When installed the flange for securing the panel in place to the window sill will be facing into the room A Hold theAccordion Panel in one hand and gently pull back the center to free th...

Page 13: ...cksAC see Fig 13 _ _ Keep a firm grip on the air conditioner carefully place the unit into the window opening so the bottom of the air conditioner frame is against the window sill Fig 5 Carefully close the window behind the top rail of the unit Extend the side panels out against the window frame Fig 6 Fig 7 Place the frame lock between the frame extensions and the window sill as shown Fig 7 Drive ...

Page 14: ...remove storm window before air conditioner is installed If Storm Window Frame must remain be sure the drain holes or slots are not caulked or painted shut Accumulated Rain Water or Condensation must be allowed to drain out RemovingAC From Window _TurnAC off and disconnect power cord Remove sash seal from between windows and unscrew safety lock _ Remove screws installed through frame and frame lock...

Page 15: ...shing you may vacuum the filter clean Note Never use hot water over 40 C 104 F to clean the air filter Never attempt to operate the unit without the air filter Cabinet Cleaning Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing deterg...

Page 16: ...Air filter may be dirty Clean filter Refer to Care and Cleaning section Todefrost set to FAN ONLY mode Thermostat set too cold for night time cooling To defrost the coil set to FAN ONLY mode Then set temperature to a Higher setting Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Temperatureis set too High set temperature to a Lower setting Air directional louver...

Page 17: ...id days OUTSIDEwhen unit is cooling Remote control not located within range Place remote control within 20 feet 180C_ Remote Sensing radius of the front of the unit Deactivating Prematurely Remote control signal obstructed Remove obstruction some models Room too cold Set temperature too low Increase set temperature 16 ...

Page 18: ...s codes 3 Proper connection to a grounded power supply of sufficient voltage replacement of blown fuses repair of loosen connections or defects in house wiring 4 Expenses for making the appliance accessible for servicing 5 Damages to finish after installation EXCLUSIONS This warranty does not cover the following 1 Failure caused by damage to the unit while in your possession other than damage caus...

Page 19: ...CS356 U 2200019005 ...