1)
Remove the fixed tape on the surface of motor
2)
Hold the corner, and dismantle the motor from one
side(without plastic clips)
3)
Remove the sealing washer by force
4)
Separate the fan motor and fin blade(pull by force)
5)
Change the motor, the reverse operation is for
assembly
Damper assembly
None
8.5
Evaporator and temperature sensing system
Evaporator in freezing chamber
1
)
Remove the air duct components in freezing
chamber.
2
)
Disconnect all connectors.
3
)
Remove the welding on inlet and outlet tubes.
4
)
Remove two screws which are used to fix the
evaporator and remove the evaporator.
Components on the evaporator
Fuse
The fuse is located on top of the evaporator
1
)
connect the fuse connector.
2
)
Cut off the band which fixes the fuse.
3
)
Separate the fuse and the evaporator.
*,Don’t break the welding of the evaporator in case that
only the fuse needs to be replaced.