miniDSP Ltd, Hong Kong /
www.minidsp.com
/ Features and specifications subject to change without prior notice
40
5.10
R
EMOTE TRIGGER TIMING
When the REMOTE MODE switch (see page 16) is set to position 2, the REMOTE OUT terminal can be used to
enable and disable power amplification.
The relevant delays can be configured from within the plugin. To do so, drop down the
Display
menu and select
Remote Power Settings
.
On the screen, enter the desired value for each time delay parameter and press the Enter key. When finished,
click the close “X” icon at the top right, and the settings will be
downloaded to the C-DSP 8x12.
(Note that the default settings are suitable 90% of installations.
So there’s no need to change from the defaults
if it’s working fine for you.
)
REM out delay
This value controls the delay from REMOTE IN going high to REMOTE OUT going high.
C-DSP turn off delay
This value controls the delay from REMOTE IN going low until the C-DSP 8x12 turns off.