Skins Game
Troubleshooting - 5
Loose
potentiometer
captivating bracket
Ensure pot captivating bracket is flush to flat of pot
shaft and retaining screw is secure.
•
Joystick
non-
functional
Faulty fuse
Replace broken fuse with identical type.
•
Button
non-
functional or
functions erratically
Poor connection
Check connection and tighten.
Faulty button
1. Place button in known working machine.
2. Replace faulty button with identical type.
•
Startup button bulb
non-functional
Faulty bulb
1. Remove bulb and inspect filament.
2. Replace faulty bulb with identical type.
•
Keypad
non-
functional or
functions erratically
Poor connection
1. Check that connections are tight.
2. Compare to Wiring Diagram to ensure accurate
connections.
Faulty keypad
1. Place keypad in known good machine.
2. Replace faulty keypad with identical type.
Coin Mechanism Problems
Symptom
Problem
Suggested Solution
Improper software
settings
1. Press TEST MODE pushbutton.
2. Access CONTROLS TEST. Confirm operation of
each coin or bill mechanism.
3. Access COIN OPTIONS. Verify that each
mechanism’s pricing and setup options are set
correctly.
•
Currency or tokens
are accepted
•
Number of credits
per coin or bill is
incorrect.
Faulty wiring
1. Check that cabinet wiring is correct.
2. Check that coin meter and coin switches connect
properly to control input wires from JAMMA
connector and CPU Board wiring.
3. Ensure coin meter and coin switches connect
properly to control input wires.
•
Currency or tokens
are accepted.
•
Startup
fails.
•
Audio and video
functional
Improper settings at
Menu System
1. Press TEST MODE pushbutton.
2. Access COIN OPTIONS. Confirm pricing and setup
of each mechanism.