Before any service work is commenced, the machine must be disconnected from the
mains.
,
Service and repair work should only be carried out by suitably qualified persons in
accordance with all appropriate local and national safety regulations.
C 4060 / C 5002 For programme operation only
C 5003
For timed operation only
C 4065 / C 4070 For programme or timed operation
I. WS 5425 / WS 5426 WS 5435 / WS 5436 WS 5445 / WS 5446
T 5205 / T 5206
PW 5065 PW 6055 PW 6065
PT 5135C PT 5136 PT 7135C PT 7136
WS 5073
T 6185
^
a) Fix the template, Fig. 1, on the machine lid and drill 6.5 mm
C
holes.
Dimensional table for drilling template:
Model
Dimension Z Dimension W
PW 5065, PW 6055, PW 6065, PT 5135C, PT 5136, PT 7135C, PT 7136
80 mm
35 mm
WS 5073, T 6185
90 mm
28 mm
WS 5425, WS 5426, WS 5435, WS 5436, WS 5445, WS 5446, T 5205, T 5206
42 mm
28 mm
Ia. WS 5425 / WS 5426 WS 5435 / WS 5436 WS 5445 / WS 5446
T 5205 / T 5206
^
b) Open the coin mechanism front panel, place the rubber mat, Fig. 2 (1), on the machine lid
above the drilled holes and secure the coin mechanism in position on the machine lid with
the fixings supplied. (If necessary, fit the reinforcement, Mat. no. 04 043 580, and locking
plate, Mat. no. 04 438 220 (7)).
^
c) Remove the cable strain relief, Fig. 2 (2), from the rear panel, pass the connection cable
(3) through and connect the plug (4) to the 7-pole round connector (5) already fitted in the
machine.
Warning!: With C 4065 and C 4070, an adapter (8) may be required (see note with the
adapter, Mat. no. 05 688 610). Secure the adapter to the wiring harness with a cable tie.
^
d) Disconnect the bridge W14, Fig. 2 (6), on the round connector (5) with C 4065 and C 4070
in accordance with the note with the adapter, Mat. no. 05 688 610.
With C 4060 and C 4070, proceed in accordance with the wiring diagram supplied with the
machine.
^
e) Open the cable strain relief, Fig. 2 (2), in the rear panel, pass the connection cable (3)
through and connect the plug (4) to the round connector. The coin mechanism fitting kit
BSK 01, Article no. 59.4000.13 (Mat. no. 04 808 770), is required.
^
f) For safety reasons the connection cable (3) must not be longer than 2.5 m.
M.-Nr. 05 719 360 / 03