Technical datasheet: PW 6207 D 

10 002 290 / 01 

11 

Technical datasheet 

Washer-extractor: 
Heating: 

PW 6207 
Steam 

Legend: 

Abbreviations in bold type:

 

Connection required 

Abbreviations in circle with dashes:

 

Connection optional or required depending on model version 

UM 

Miele base 

UO 6020 (UO = open base) 
Height 

7

/

16

"

240 mm 

Width 

35 7/16" 

900 mm 

Depth 

39 

3

/

4

"

1009 mm 

UG 6020 (UG = closed-in base) 
Height 

7

/

16

"

240 mm 

Width 

36 

1

/

4

"

920 mm 

Depth 

40

 

1

/

8

"

1019 mm 

BS 

Concrete base

Quality and density of concrete must comply with load. 
Concrete base must be firmly secured to floor! 
Recommended height 

7

/

16

"

240 mm 

Minimum height 

3 15/16" 

100 mm 

Minimum width 

36 

1

/

4

"

920 mm 

Minimum depth 

41 

5

/

16

"

1050 mm 

DAV 

Steam

connection valve

 

The steam valve regulating the steam flow must be provided 
on-site. 

Pneumatic Steam Valve (PND) 

Adjustable steam pressure 

0 - 145 psi 

0 - 1000 kPa 

Connection size 

1/2" 

The connection and the pneumatic valve controller must be 
provided on-site. 

Summary of Contents for PW 6207 D

Page 1: ...lation plan Washer PW 6207 D Steam Heated Always read operating and installation instructions before Installation and Commissioning This is for the protection of yourself and your machine en US 10 002 290 01 ...

Page 2: ...2 10 002 290 01 It is essential to read the operating and installation instructions before installing commissioning or using the machine This avoids the risk of accidents or damage All rights reserved ...

Page 3: ...10 002 290 01 3 Machine dimensions measurements in millimeters ...

Page 4: ...4 10 002 290 01 Connections measurements in millimeters ...

Page 5: ...10 002 290 01 5 Machine dimensions measurements in millimeters ...

Page 6: ...6 10 002 290 01 Machine dimensions measurements in millimeters ...

Page 7: ...10 002 290 01 7 Machine dimensions measurements in inches ...

Page 8: ...8 10 002 290 01 Connections measurements in inches ...

Page 9: ...10 002 290 01 9 Machine dimensions measurements in inches ...

Page 10: ...10 10 002 290 01 Machine dimensions measurements in inches ...

Page 11: ...d in base Height 9 7 16 240 mm Width 36 1 4 920 mm Depth 40 1 8 1019 mm BS Concrete base Quality and density of concrete must comply with load Concrete base must be firmly secured to floor Recommended height 9 7 16 240 mm Minimum height 3 15 16 100 mm Minimum width 36 1 4 920 mm Minimum depth 41 5 16 1050 mm DAV Steam connection valve The steam valve regulating the steam flow must be provided on s...

Page 12: ...mend connecting the appliance via a plug connection so that an electrical safety check can be carried out e g during repair or maintenance If it is necessary to install a residual current device RCD in accordance with the local regulations a residual current device type B AC DC sensitive must always be used PA Potential equalization Externally threaded supports for shrims and nuts If necessary equ...

Page 13: ...ld water valve KWH Cold water Water pressure Min flow rate 14 5 psi 100 kPa Hard water Water pressure Max flow rate 145 04 psi 1000 kPa Max volume flow 8 45 gal min 32 l min Threaded connector fitting at site as per DIN 44 991 flat sealing 1 external thread Length of connector hose 59 1 16 1500 mm Avarage water requirement for a standard program 60 colored washing determined at cold hot and hard w...

Page 14: ...h 8 mm x 80 mm 4 x screw anchors Ø x length 5 16 x 3 1 8 1 2 x 2 3 8 12 mm x 60 mm The installation and assembly of the appliance and base must follow the installation instructions provided Machine data Width 36 3 8 924 mm Depth 44 1 2 1130 mm Height 55 1 8 1400 mm Housing width 36 1 4 920 mm Housing depth 40 3 16 1020mm Width loading opening clear width 36 5 8 930 mm Recommended wall spacing to r...

Reviews: